CS-C73KE
Installation Information
Indoor / Outdoor unit installation diagram
Length of power supply cord
about 1.1 m
< <
CU-C123KE
10 cm
or more
• This illustration is for explanation purposes only.
The indoor unit will actually face a different way.
Piping direction
about 1.8 m
Right
Right
<
<
rear
Right bottom
5 cm or
more
Air purifying filter 5
(Left and right are identical)
Insulation of piping connection
•
Carry out insallation
after checking for gas
leaks.
•
After securing with
three of the vinyl
tape 7, wrap with
vinyl tape 8.
Saddle (*)
Connecting cable
(3-CORE WIRE/1.5 mm
Locally approved cable.
Additional drain hose (*)
1/4" Liquid side piping (*)
Gas side piping (*)
1/2"
(Front side)
Left
Left
rear
Left bottom
Installation plate 1
Sleeve (*)
Bushing-Sleeve (*)
Vinyl tape
8
Vinyl tape 7
CU-C73KE
CU-C93KE
2
)
10 cm
or more
– 25 –
Attention not to bend up drain hose
Installation parts you must
purchase (*)
Putty, (Gum Type Sealer) (*)
Bend the pipe as closely on the
wall as possible, but be careful
that it doesn't break.
Vinyl tape (Wide) (*)
• Apply after carrying out a
drainage test.
• To carry out the drainage
test, remove into the air filters
and pour water into the heat
exchanger.
Saddle (*)
Connecting cable
(3-CORE WIRE/1.5 mm
Locally approved cable.
Additional drain hose (*)
1/4" Liquid side piping (*)
Gas side piping (*)
3/8"
Vinyl tape (*)
(Narrow)
2
)