Preparing The Connections - Viessmann Vitodens 200 WB2 Installation Instructions Manual

Wall-mounted, gas-fired condensing boiler
Table of Contents

Advertisement

Boiler

Preparing the connections

Gas/water connections
500
SVL
SRL
WW
KW
HV
GA
HR
A Boiler dimensions
Legend
ADG Expansion vessel, c'' coupling
GA Gas connection, b'' dia.
HR
Heating return, c'' coupling
HV
Heating flow, c'' coupling
4
5862130G - page 4 (Black)
Screen angle and frequency: 45.0000, <default>
403
ADG
Gas combination boiler only:
KW Cold water, b'' coupling
WW Hot water, b'' coupling
Gas central heating boiler only:
SRL Cylinder return, c'' coupling
SVL Cylinder flow, c'' coupling
See installation instructions
for the mounting aid or
mounting frame regarding
preparation of the gas,
water and electrical connec
tions on site.
A room height of 2300 mm is re
quired for installation of the boiler
with the domestic hot water cylinder
positioned under the boiler.
It is not necessary to observe a mini
mum clearance from combustible
materials as the maximum permis-
sible surface temperature of 85 ºC is
not exceeded at the rated output.
If the Vitodens boiler is to be in
stalled in a bathroom or shower
room, it should be positioned so that
it cannot be touched by anyone
using the bath, shower or hand wash
basin (see safety zones and mini
mum wall clearances as defined by
VDE 0100)!
The maximum ambient temperature
should not exceed 35 ºC.