M6040, M7040Narrow, WSM

(2) Blower Resistor

Temperature Control Dial Checking
1. Turn the temperature control dial counterclockwise till it stops
(at "COOL" position).
2. Measure the voltage with a voltmeter across the terminal b and
terminal d. Make the following measurement with the terminals
connected.
3. Turn the main switch to "ON" position.
4. Check that an output voltage is approximately 10 V when
turning the temperature control dial clockwise till it stops
("WARM" position).
5. Turn the main switch back to "OFF" position.
6. Turn the temperature control dial clockwise till it stops
("WARM" position).
7. Measure the voltage with a voltmeter across the terminal d and
terminal b. Make the following measurement with the terminals
connected.
8. Turn the main switch to "ON" position.
9. Check that an output voltage is approximately 10 V, when
turning the temperature control dial counterclockwise till it stops
("COOL" position).
10. If an output voltage differs from approximately 10 V, the control
panel, wiring harness of fuse is faulty.
(1) 16P Connector (Switch Side)
(2) 16P Connector (Wire Harness Side)
A/C Blower Resistor
1. Remove the outer roof.
2. Disconnect the 4P connector (1) for A/C blower resistor (2).
3. Measure the resistance with an ohmmeter across the R1
terminal and E terminal, and across the R2 terminal and E
terminal.
4. If the factory specifications are not indicated, A/C blower
resistor is faulty.
Factory
Resistance
specifica-
tion
(1) A/C Blower Resistor Connector
N10-S5
(A) "COOL" position to "WARM"
position
(B) "WARM" position to "COOL"
position
9Y1210220CAS0008US0
R1 terminal –
Approx. 0.56 Ω
E terminal
R2 terminal –
Approx. 1.56 Ω
E terminal
(2) A/C Blower Resistor
9Y1210220CAS0009US0
KiSC issued 07, 2012 A