Connector Voltage
1. Draw out the control panel (1).
2. Disconnect the 16P connector (2) from control panel switch.
3. Turn the main switch to "ON" position.
4. Measure the voltage with a voltmeter across the terminal o and
terminal a.
5. If the voltage differs from the battery voltage, the wiring harness,
A/C relay or fuse is faulty.
Terminal o –
Voltage
Terminal a
(1) Control Panel
(2) 16P Connector (Switch Side)
A/C Switch Checking
1. Measure the voltage with a voltmeter across the terminal k and
chassis.
2. Turn the main switch to "ON" position.
3. Turn the blower switch to "ON" position.
4. Press the air conditioner switch to set it at "OFF" position
(indicator : OFF), and then measure a voltage using a circuit
tester.
5. Press the air conditioner switch to set it at "ON" position
(indicator : ON), and then measure a voltage using a circuit
tester.
6. If a measured voltage does not comply with the values in the
table below, the control panel, wiring harness or fuse is faulty.
Terminal k –
Voltage
Chassis
(1) 16P Connector (Switch Side)
Mode Control Dial Checking
1. Disconnect the 16P connector from control panel switch.
2. Check the continuity through the switch with an ohmmeter.
3. If the continuity specified below is not indicated, the switch is
faulty.
(1) 16P Connector (Switch Side)
N10-S4
Approx. battery voltage
(3) 16P Connector (Wire Harness Side)
9Y1210220CAS0005US0
A/C switch at
Approx. battery voltage
ON
A/C switch at
Approx. 1 V
OFF
(2) 16P Connector (Wire Harness Side)
9Y1210220CAS0006US0
9Y1210220CAS0007US0