POWER SUPPLY

WARNING: THIS APPLIANCE MUST BE EARTHED.
THIS APPLIANCE IS DESIGNED FOR THE VOLTAGE STATED ON THE RATING PLATE, WHICH IS SITUATED BEHIND
THE PLINTH COVER.
A 1PH 32 amp 230V or 3PH 400V minimum 16A per phase ~ 50 Hz fused electrical supply is required adjacent to the
appliance. External wiring to the unit must be installed using the mains cable provided, in accordance with the current wiring
regulations and any local regulations which apply. If cable is shortened, new ferrules must be fitted to the stripped
conductors.
The method of connection to the mains electricity supply must facilitate complete electrical isolation of the appliance, by a
multi-pole switch, having a contact separation of at least 3mm on all poles.
The isolator should not be positioned immediately above the cooker, but must be fitted within 2 metres of the appliance.
The isolator maybe separate from the connection point.
The mains connection point must be accessible within the areas shown in Fig 10, Page 10 for cable routing options.
A fully recessed cooker connection box may be located immediately behind the cooker (in the hatched area only as shown
in Fig. 11), however the 25mm spacers (provided with the appliance) must be fitted.
For 2 or 3 phase installations an optional adaptor kit must be obtained (Part No. AE4M280352).