8-2. Installation Diagram of Indoor and Outdoor Units

5
Sasa-Zeolite Vitamin C filter
Bef ore installing the
wireless remote control
• With the remote control cover
open, load the batteries supplied
correctly, observing their polarity.
2
Wireless remote control
Cover
3
Batteries
Hook
6
Bio-enzyme & Gingko filter
8
Pan head wood screw
4
Remote control holder
2
Wireless remote
control
Vinyl tape
Apply after
carrying out a
drainage test.
Electric parts cover
Loop the connective cable
(about 100 mm in diameter
and 300 – 350 mm long).
Fig. 8-2-1
– 24 –
FILE NO. SVM-06017
For the rear left and left
piping
Hook
1
Installation
plate
Insert the cushion between
the indoor unit and wall,
and tilt the indoor unit for
better operation.
Shield
Do not allow the drain hose
pipe
to get slack.
Make sure to run the drain
hose sloped downward.
The auxiliary piping can be
connected the left, rear left,
rear right or bottom.
Right
Rear
Saddle
Extension
drain hose
(Not available,
provided by
installer)
Insulate the refrigerant
pipes separately with
insulation, not together.
6 mm thick heat resisting
polyethylene foam
Wall
Cut the piping hole
sloped slightly
Rear left
Bottom
Left