• Connect the indoor unit with a Mitsubishi Lossnay ventilator
Indoor
and the function selection of the remote controller can be
unit
used to change the fan speed of the Lossnay and operate it
linked with or independent of the indoor unit.
Remote
controller
• It can obtain the humidifying signal linked to the heater
operation of the air conditioners.
• Temperature sensors for the air conditioners are provided as
standard equipment at the intake port of the indoor unit and
two locations of the wired remote controller. The function
selection from the wired remote controller can be used for
switching.
• If the sensor in the intake port of the indoor unit is replaced
with a "Temperature Sensor" (sold separately), it can be
externally mounted.
• If a dedicated outdoor unit is used, it can be connected to a
Dedicated
MELANS system controller (for M-NET).
outdoor
• The hand held remote controller is the Slim A control remote
unit
controller .
• In the restriction of the MELANS system, the number of
Indoor
unit
indoor units controlled is calculated as the number of dedi-
cated outdoor units in the case of the A controller. (Any of
from among simultaneous twin, triple and quad is counted
Remote
as one unit.)
controller
• Number of dedicated outdoor units controlled:
Central controller (MJ-102MTR-B): 50 units
Multi-panel controller (MJ-111AN-B): 50 units
Group remote controller (PAC-SC30GR): 16 units
• It is possible to form blocks (collections of multiple groups)
Dedicated
to obtain contact points for operation settings (starting, stop-
outdoor
ping) and contact points for status monitoring (operation,
unit
error).
MB-101: Maximum of 48 contact points. 12 blocks.
Indoor
unit
MB-102: Maximum of 96 contact points, 24 blocks.
• Operation setting
Starting and stopping can be done by block units or all at
Remote
once.
controller
• Status monitoring
It is possible to monitor operation or stop status and error or
normal operation status.
Display
device
• When outdoor controller board receives demand signals,
outdoor unit is suspended and indoor units run under "fan"
operation mode.
Outdoor unit
Indoor unit
Features
132
Parts To Be Procured
(Sold separately or
obtained locally.)
• Wired remote
controller
• Lossnay operating
cable
(PAC-SB81VS)
• Wired remote
controller
• Temperature sensor
(PAR-SE40TS-E)
• Outdoor unit for con-
necting to M-NET
• Central controller
(MJ-102MTR-B)
• Group remote
controller
(PAC-SC30GR)
• Multi-panel controller
(MJ-111AN-B)
• Outdoor unit for
connecting to M-NET
• Parallel interface kit
(MB-101, MB-102)
• Adapter to input
external demand
signals
(PAC-SC36NA)
• Relay circuit
(PAC-SA86SK)