WarmFlow BoilerhouseB70HE User Manual page 67

High efficiency condensing boilers
Table of Contents

Advertisement

1. FIT DIVERTER ASSEMBLY SEALS
Apply suitable lubricant to the two Diverter
Assembly Seals (supplied loose) then fit to
the end of the boiler flue pipe noting the
correct orientation.
The seals MUST be fitted as shown with
the outer surface sloping away from the
end of the pipe to allow the Diverter
Assembly to push over the seals.
2. FIT SPLIT RING-NUT
Fit the Split Ring-nut by pulling open the split and
pushing the nut over the pipe. Ensure the threaded
end is facing towards the seals.
3. FIT & SECURE DIVERTER ASSEMBLY
Lubricate the inside of the Diverter Assembly „B‟
then push the assembly onto the end of the pipe
and over the 2 seals. Use the Split Ring-nut to force
the seals into the assembly ensuring that they remain
flat on the pipe.
Tighten the Ring-nut into the assembly ensuring the
assembly is tight onto the end of the pipe and that the
seals are well compressed. The Diverter Assembly
should be firmly attached to the pipe when complete.
4. ADJUST DIVERTER ASSEMBLY
Turn the 90° bend on the Diverter Assembly „B‟ around
to 45°, pointing towards the wall. If necessary, adjust
the position of the rubber dresser on the Diverter
Assembly in order to ensure a good weather seal.
5. ASSEMBLE PLUME MANAGEMENT KIT
Assemble the remainder of the Plume Management Kit
as shown over the page, securing the whole assembly
into place using the Mounting Brackets „E‟ .
It will be necessary to cut one of the Extensions „F‟ to form Short Extension „C‟,
depending on the spacing of the boiler from the wall.
If fitting the flue extension pipe (on a 150HE or Combi model), glue the rubber
dresser of the Diverter Assembly „B‟ to the boiler casing using silicone sealant in
order to secure the assembly in place.
Ensure the location of the terminal complies with all local legislative requirements.
Page 65