Download Print this page

Carrier A07049 Installation Instructions Manual page 42

Performance series ac/hp

Advertisement

provides temperature
protection forthe home i n theselected mode, butnot
comfort. When vacation mode i s active, anarrow will bedisplayed
beside
"VACATION"
inthe upper leftcorner ofthe display.
Vacation Setpoints
Aspecial set o ftemperature
setpoints
exist which a re active i nvacation mode.
They a re adjustable
bythe homeowner,
are exclusively
forvacation mode, and
are remembered
from one vacation selection
tothe next. See T able 2fordefault
values.
Table 2 - Vacation
Setpoints
Default
Values
MODE
AUTO
Fan
Auto
Heat Setpoint
55°F/13°C
Cool Setpoint
85°F/29°C
OPERATIONAL
INFORMATION
Timers
Five-Minute
Compressor
Timeguard
This timer prevents
compressor
from starting
unless
it has been off for at least 5
minutes.
It can be overridden
for 1 cycle by simultaneously
pressing
FAN and
UP buttons.
Cycle Timer
Based on the selection
of 2, 4, or 6 cycles
per hour, this timer is set to 30, 15, or
10 minutes.
This
much
time
must
elapse
from
the start of one cycle before
another
cycle can start. It serves
to impose
the cycles
per hour limits.
It can be
defeated
for one cycle by simultaneously
pressing
the FAN and UP buttons.
41