Installation, Start-Up, and Operating Instructions
NOTE: Read the entire instruction manual before starting the
installation.
SAFETY CONSIDERATIONS
Read and follow manufacturer instructions carefully. Follow all
local electrical codes during installation. All wiring must conform
to local and national electrical codes. Improper wiring or installa-
tion may damage thermostat.
Recognize safety information. This is the safety-alert symbol
When you see this symbol on the equipment and in the instruction
manual, be alert to the potential for personal injury.
Understand the signal words DANGER, WARNING, and CAU-
TION. These words are used with the safety-alert symbol. DAN-
GER identifies the most serious hazards which will result in severe
personal injury or death. WARNING signifies a hazard which
could result in personal injury or death. CAUTION is used to
identify unsafe practices which would result in minor personal
injury or product and property damage.
INTRODUCTION
Carrier's 7-day programmable thermostats are wall-mounted, low-
voltage thermostats which maintain room temperature by control-
ling the operation of a heating and air conditioning system. All of
the thermostats allow up to 4 time/temperature settings to be
programmed per 24 hr period and store programs for 7 indepen-
dent days. Batteries are not required; during a power interruption,
the internal memory stores programs for an unlimited time and the
clock continues to run for at least 72 hrs.
INSTALLATION CONSIDERATIONS
Power
Note that all TSTAT models have no batteries and are not "power
stealing". They do require 24VAC (R and C terminals) to be
connected for proper operation. Thermostat will not operate
without these 2 connections.
Models
There are 3 different models. The last 2 letters of the part number
indicate the model. These 2 letters appear on the package and on
the circuit board. Be sure to have the proper thermostat for the
intended application. Models are:
AC - 1-stage cool, 1-stage heat - for AC systems only.
HP - 1-stage cool, 2-stage heat - for either HP or AC with 2-stage
heat.
2S - 2-stage cool, 2-stage heat - for 2-speed AC systems, or
2-stage cool, 3-stage heat - for 2-speed HP systems, or
1-stage cool, 4-stage heat - for 1-speed HP with special
3-stage electric heat.
Use each only for its intended purpose. (See Table 1.)
INSTALLATION
Step 1—Thermostat Location
Thermostat should be mounted:
• Approximately 5 ft (1.5m) from floor.
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Book 1
4
PC 101
Tab misc. misc.
Catalog No. 92-33TS-TA1C
Printed in U.S.A.

Programmable Thermostats

.
®
Fig. 1—Carrier Programmable Thermostat
• Close to or in a frequently used room, preferably on an inside
partitioning wall.
• On a section of wall without pipes or duct work.
Thermostat should NOT be mounted:
• Close to a window, on an outside wall, or next to a door leading
to the outside.
• Exposed to direct light and heat from a lamp, sun, fireplace, or
other temperature-radiating object which may cause a false
reading.
• Close to or in direct airflow from supply registers and return-air
grilles.
• In areas with poor air circulation, such as behind a door or in
an alcove.
Step 2—Set Dip Switches
There are 4 dip switches on the back of the circuit board which
must be set depending on the application. Check each switch for
correct position.
Switch A - Zoning Select (Active on all models)
Set switch A to ON for zoning, OFF for non-zoned installations.
Do not set switch A to ON in a non-zoning application, as
equipment will cycle excessively. When switch A is set to OFF,
equipment is limited to 4 cycles per hr and a 5-minute timeguard
protects the compressor.
Switch B - Setback Recovery (Active on all models)
Set switch B to ON for normal recovery, OFF for smart recovery.
Normal recovery adjusts the desired temperature at the pro-
grammed time. Smart recovery, which is active in heating mode
only, starts earlier and adjusts the desired temperature slowly so
that room temperature will arrive at the programmed temperature
at the programmed time.
Switch C - HP/AC Select (Active on HP and 2S models only)
Set switch C to ON for AC only, OFF for HP applications.
Form TSTAT-1SI
A94134
Pg 1
9-94
Replaces: New

Advertisement

Table of Contents
loading

Summary of Contents for Carrier A94134

  • Page 1: Programmable Thermostats

    INTRODUCTION • On a section of wall without pipes or duct work. Carrier’s 7-day programmable thermostats are wall-mounted, low- Thermostat should NOT be mounted: voltage thermostats which maintain room temperature by control- ling the operation of a heating and air conditioning system. All of •...
  • Page 2 Table 1—Model Selection and Wiring Diagram Chart AIR CONDITIONER HEAT PUMP OUTDOOR UNIT 1 Speed 2 Speed 1 Speed 2 Speed 1-Stage Model AC Model 2S Requires Model 2S Furnace See Fig. 2 See Fig. 8 Interface Control See Fig. 11 2-Stage Model AC Model HP...
  • Page 3: Fan Operation

    2. Pressing the FAN button alternately selects AUTO or ON fan MODEL AC SINGLE-STAGE SINGLE-SPEED THERMOSTAT FURNACE AIR CONDITIONER operation. Fan annunciator displays the current selection. 3. Pressing the MODE button will select OFF, HEAT, COOL, 24 VAC HOT and AUTO. Heat pumps also have an EHEAT mode. Mode annunciator displays the current selection.
  • Page 4: Fan Coil

    TWO-STAGE OR MODEL HP TYPICAL SINGLE-SPEED MODEL HP SINGLE-SPEED VARIABLE-SPEED THERMOSTAT FAN COIL AIR CONDITIONER THERMOSTAT AIR CONDITIONER FURNACE 24 VAC HOT 24 VAC HOT HEAT STAGE 1 W/W1 HEAT STAGE 1 W/W1 W/W1 COOL STAGE 1 Y/Y2 Y/Y2 COOL STAGE 1 Y/Y2 Y/Y2 HEAT STAGE 2...
  • Page 5 MODEL 2S SINGLE-STAGE TWO-SPEED MODEL 2S TYPICAL TWO-SPEED THERMOSTAT FURNACE AIR CONDITIONER THERMOSTAT FAN COIL AIR CONDITIONER COOL STAGE 1 Y1/W2 24 VAC HOT HEAT STAGE 1 W/W1 HEAT STAGE 1 W/W1 COOL STAGE 2 Y/Y2 Y/Y2 * COOL STAGE 2 Y/Y2 O/W2 HEAT STAGE 2...
  • Page 6: Wiring Diagram Notes

    MODEL 2S TWO-STAGE OR TWO-SPEED MODEL 2S FK4B SINGLE-SPEED THERMOSTAT FAN COIL HEAT PUMP THERMOSTAT VARIABLE-SPEED HEAT PUMP FURNACE COOL/HEAT 24 VAC HOT Y1/W2 STAGE 1 RVS COOLING O/W2 HEAT STAGE 2 W/W1 W/W1 HEAT STAGE 3 W/W1 COOL/HEAT Y/Y2 Y/Y2 COOL/HEAT Y/Y2...
  • Page 7: Operational Information

    OPERATIONAL INFORMATION Five-minute Compressor Timeguard This timer prevents the compressor from starting unless it has been off for at least 5 minutes. It can be defeated for 1 cycle by simultaneously pressing the FAN mode button and the INCREASE TEMPERATURE button. Fifteen-minute Cycle Timer This timer prevents the start of a heating or cooling cycle until at least 15 minutes after the last start of the same cycle.