Error Codes - Philips FTL2.1E Service Manual

Table of Contents

Advertisement

EN 18
5.
FTL2.1, FTL2.2E AA
Mains cord IN
OTC gets supply voltage
OTC resets, Initialise IO pins
Read NVM identification
start time extraction
start P50 recording
start EPG loading
Stand-by
Standby bit = off
Ambient light ON
Trapped Startup 1
Put Stand-by line LOW
CPU GO becomes HIGH
Set STBYEN,VCCON,PFCON = 1
Only FHP (opt 2, 8)
Keep sound amplifiers muted with
sound enable = high
+5V and +8V is switched on
+8V and +5V get their nominal level,
detected by the OTC
activate protection algorithms for +8V and +5V and
I²C (start I²C protection the moment the component
is initialised).
Trapped Startup 2
Read rest of NVM information
Initialize HIP: IF, source selection, 2fh input, video
processing
Switch on the syncoutput: set_syncout_tristate= off
Initialize tuner
Initialize 3D Combfilter
or Initialize Columbus
Initialize PICNIC + screen info
Initialize rest of PIP/DW module
Start TXT acquisition
and time extraction
Reset Audio = low
and Initialize MSP
Initialize EBILD
Screen type
Start up LCD
Initialize PDP FHP
opt 3,4,5,6
opt 2,8
Figure 5-3 Stepwise start-up part 1
Start up LCD
Start
Stand-by bit set ?
yes
Trapped Startup 3
Semi stand by
Figure 5-4 Stepwise start-up part 2
Note (*):
When the set is in stepwise mode and, due to stepping-up,
a protection is activated, the set will really go into protection
(blinking LED). The set will not leave the stepwise-mode
however. If state X is the state where the set went to
protection, stepwise start-up will return to state X-1. At
state (X-1) diagnostic measurements can be performed.
Also, in the short time the set is in state X but not yet in
protection, you can also do some measurements.
Service Modes, Error Codes, and Fault Finding
OUT
Reset Audio=high
enable watchdog
Tact switch
OFF
Stand-by bit = OFF
400msec>t>200msec
Initialize PDP SDI
E_14620_048.eps
opt 0,1,7
no
LCD ON
Ebild Power ON
Output Blanking OFF
LAMP ON
ON
Trapped Startup 4
E_14620_049.eps
5.4.4
How To Connect
This is described in the chassis fault finding database in
ComPair.
Figure 5-5 ComPair interface connection
5.4.5
How To Order
ComPair order codes (EU/AP/LATAM):
Starter kit ComPair32/SearchMan32 software and
ComPair interface (excl. transformer): 3122 785 90450.
ComPair interface (excl. transformer): 4822 727 21631.
Starter kit ComPair32 software (registration version): 3122
785 60040.
Starter kit SearchMan32 software: 3122 785 60050.
ComPair32 CD (update): 3122 785 60070 (year 2002),
3122 785 60110 (year 2003 onwards).
SearchMan32 CD (update): 3122 785 60080 (year 2002),
3122 785 60120 (year 2003), 3122 785 60130 (year 2004).
ComPair firmware upgrade IC: 3122 785 90510.
Transformer (non-UK): 4822 727 21632.
Transformer UK: 4822 727 21633.
ComPair interface cable: 3122 785 90004.
ComPair interface extension cable: 3139 131 03791.
ComPair UART interface cable: 3122 785 90630
Note: If you encounter any problems, contact your local
support desk.
170504
5.5

Error Codes

5.5.1
Introduction
The error code buffer contains all detected errors since the last
time the buffer was erased. The buffer is written from left to
right, new errors are logged at the left side, and all other errors
shift one position to the right.
When an error has occurred, the error is added to the list of
errors, provided the list is not full or the error is a protection
error.
When an error occurs and the error buffer is full, then the new
error is not added, and the error buffer stays intact (history is
maintained), except when the error is a protection error.
To prevent that an occasional error stays in the list forever, the
error is removed from the list after 50+ operation hours.
170504
When multiple errors occur (errors occurred within a short time
span), there is a high probability that there is some relation
between them.
5.5.2
How to read the Error Buffer
Use one of the following methods:
On screen via the SAM (only if you have a picture).
Examples:
0 0 0 0 0: No errors detected
6 0 0 0 0: Error code 6 is the last and only detected
error
9 6 0 0 0: Error code 6 was first detected and error code
9 is the last detected error
Via the blinking LED procedure (when you have no
picture). See next paragraph.
Via ComPair.
TO
TO
I 2 C SERVICE
UART SERVICE
CONNECTOR
CONNECTOR
I 2 C
PC
VCR
Power
9V DC
E_06532_021.eps
180804

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ftl2.2e

Table of Contents