Philips FTL2.1E Service Manual page 129

Table of Contents

Advertisement

Circuit Descriptions, Abbreviation List, and IC Data Sheets
9.2
Power Supply LCD
9.2.1
General
Changes in 2004:
All displays:
The sound supplies are +18V and -18V.
A loudspeaker DC protection is added (via TS7030 on
the Main Supply).
A POK (Power OK) is generated when the 12V from
the Aux supply is stabilised.
The STAND-BY supply is integrated in the Sound
Amplifier panel.
For Sharp displays (32") only:
12V supply for the lamps i.s.o. 24V.
12V to 5V DC/DC converter on SSB.
9.2.2
Block Diagram
Supply LCD 2004
110-230V
Block B
Block A
Relay Switch
Input filter
Relay Control
MUTE
GENERATOR
MUTE
Audio
Figure 9-3 Block diagram LCD power supply
Main Supply (Block "D")
Diversity
Mains input voltage diversity (1308):
EU: 198 - 264 V
US: 108 - 132 V
AP multi: 90 - 275 V
control IC and triac).
China: 160 - 270 V
Mains filter diversity:
EU, China: 1 x mains filter + harmonic coil.
US, AP: 2 x mains filter + inrush current resistor.
Screen size diversity:
One module for 30" to 37" sets.
Two (almost identical) modules on one PWB for 42"
sets.
Specifications
12 V / 3 A on connector 1304 (for Ambient Light and to
generate +8V6).
24 V / 5 A for LCD backlight on connector 1304 (for Sharp
12 V, 9 A).
+18V, -18V sound on connector 1M02.
+8V6 (derived from +12V from the Main Supply, switched
"off" in Stand-by).
Output voltage: over-voltage protection of resonant supply.
Output current protection of resonant supply.
Current protection at some safety fault conditions.
Stand-by mode
The resonant supply is switched "off" via relay 1450 that is
driven by the Stand-by Supply (via connector 1305).
+24V lamp(+12V for Sharp)
+12V
Block C
Block D
Rectifier
LCD Aux
+8V6
Doubler
Supply
+18V Sound
-18V Sound
DC prot
V tuner
Block E
Stand By
+5Vsw
Supply
+5V2
Stby
5Vrelay
5V2
3V3
POR
Blue LED
OTC
Stby LED
Audioprotect
TACT
switch
E_14620_010.eps
.
AC
(doubler).
AC
(auto doubler with AVS10
AC
.
AC
Outputs
130-400 V
1306).
Mains over-voltage and safety protection for Stand-by
Supply (connector 1307).
Inputs
Relay drive voltage (for STAND-BY/ON mode) on
connector 1305.
DC_PROT signal to protect loudspeakers when there is a
DC voltage across the loudspeakers (1M02).
1304
12V
Opto
HOT
Control supply
070504
25V_HOT
(Startup)
1307
(RES)
1306
1305
Figure 9-4 Functional diagram Main Supply (one module)
Stand-by Supply (Block "E")
The Stand-by Supply is based upon the "Fly Back Converter"
principle. A description of this principle can be found in the
FM2x Service Manuals.
FTL2.1E, FTL2.2E
(full range) for Stand-by Supply (connector
DC
Audio Supply
DC prot
18V
1M02
Reference
Heatsink
+24V
+12V
24V
COLD
GND_AUD
Resonant Trafo
Driver Trafo
MC34067P
+400V
Doubler
+400V
Bridge
+400V
Rectifier
1
Stand By supply
Relais
HOT
COLD
EUR / CHINA
Mains filter
Mains Harmonic
Mains filter
HOT
COLD
9.
EN 129
-18V
GND_SND
Heatsink
+12V
Heatsink
AVS10
US / APmulti
Bridge
Rectifier
Inruch
US / APmulti
EUR / CHINA
US / APmulti
1308
Mains input
E_14620_025.eps
100504

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ftl2.2e

Table of Contents