Nozzle check settings
Sets the nozzle check.
Item
Nozzle check
Nozzle Verification
settings
Technology
Threshold of
clogged nozzles
Additional auto
nozzle check
during printing
Nozzle check
interval
Operations when
Dot substitution
clogged nozzle
Operation at
detected
clogged nozzle
Description
Enables/disables the auto nozzle check.
Sets the threshold of clogged nozzles.
The standard setting is '0'.
Sets the additional auto nozzle check during printing.
Sets the nozzle check interval for when executing the additional
auto nozzle check during printing.
Enables/disables the dot substitution.
Sets the operation during nozzle clogging.
Chapter 3
Handling
105