3 SERVICE
SSB ATTACK
A = 0.5V/div
B = 5V /div.
23.
Set the timebase on the oscilloscope to 200 msecs/div.
24.
Control that the oscilloscope displays the response shown in figure SSB decay.
SSB DECAY
A = 0.5V/div.
B = 5V /div.
25.
Select test programme SP-04-7.
26.
Set the timebase on the oscilloscope to 50 msecs/div.
27.
Set the signal generator in amplitude modulation mode, modulating LF signal 1.0 kHz and
modulating index M = 0.3.
28.
Control that the oscilloscope displays the response shown in figure AM attack and decay.
PAGE 3-16
20 msecs/div
200 msecs/div.