Regulator Operation Modes - Jøtul ERS 01 Operation And Maintenance Manual

Electronic flame controller
Table of Contents

Advertisement

ENGLISH
Fig. 23 Exit
In order to exit the menu, position the cursor on icon and push
the knob. After Timeout time elapses, the device will switch
to the main window or to parent menu if the regulator is in a
nested menu
9.1
Presetting temperatures
Presetting temperature in the regulator is performed in steps
which are related to preset temperatures of exhaust gases. To
achieve more precisely optimized working temperatures it is
recommended to reduce the temperature range between Tzmin
and Tzmax. There are 11 positions for presetting temperature of
exhaust gases in the regulator. Temperatures corresponding to
particular position depend on user parameters setting.
User sets a minimum value of preset temperature (for position
no. 1) with the use of Tzmin parameter and maximum value of
preset temperature (for position no. 11) with the use of Tzmax
(Applicable parameters see section "Burning options"). After
setting Tzmin and Tzmax values, the regulator will automatically
calculate position thresholds from 2 to 10 proportionally
according to figure below.
Fig. 24 Preset temperature positions
Temperatures in the ERS 01 regulator are preset directly from
the main window or via menu system.
In order to determine a suitable working temperature, it is
necessary to take into account several different factors, such as:
the length of connection to the chimney, draught in the smoke
duct, the quality and volume of firewood. If the user observes
the temperature recommended by the producer is not sufficient
for the effective functioning of a fireplace, the user can select
another temperature out of 11 set temperature options (by
increasing or reducing the temperature's value).
Attention! It is not recommended to use low temperature
ranges.
Attention! For restoring default parameters see section
"Restoring default parameters".
12
In order to preset temperature directly from the main window:
Presetting temperatures from menu level is performed similarly.
Selecting "Preset temperature" in the menu enables to choose
11 positions of a preset temperature. After entering the menu,
the cursor will position itself by default on currently preset
temperature.
To leave the menu without selecting any temperature, click
Return Icon.
Depending on the current operation mode
(An outline of the operation modes can
be found under section „Flame controller
operation modes"), the following editions
are available on the main screen:
Presetting temperature
Presetting throttle opening
10.0 Regulator operation
modes
The regulator is equipped with four operation modes: "Firing
up", "Automatic" and "Manual".
In order to select operation mode of the regulator, select
"Operation modes" in MENU. The lower menu level with
operation modes will be displayed on the screen. Turn the knob
to select the required mode
By turning the knob, set the
cursor on temperature values
in a frame. There is a number
of position visible on a left
side of the frame.
Pushing the knob in select
mode will result in blinking
value and switching into
edition mode.
Turning the knob in edition
mode results in changing
this value.
Click again in order to
confirm changed value and
to switch into selection
mode (the regulator
accepted the value and will
take appropriate action).
X
X
X