This boiler cannot be used with all types of chimneys. Read these
instructions carefully before installing.
These Gas-Fired Hot Water Boilers are low pressure, sectional cast
iron boilers Design Certified by C.S.A. (Canadian Standards Associ-
ation) for use with Natural and Propane Gases. They are constructed
and hydrostatically tested for a maximum working pressure of 50 psi
in accordance with A.S.M.E. Boiler and Pressure Vessel Code Sec-
tion IV Standards for cast iron heating boilers.
Figure 1 - Boiler ratings and Capacities
Number of
Model
Sections
XEB-2
XEB-3
XEB-4
XEB-5
XEB-6
XEB-7
* MBH = 1,000 Btuh = British Thermal Unit Per Hour. Boilers are equipped for altitudes up to 2,000 feet only. U.S.A. Only - For altitudes above 2,000 feet, ratings should be reduced at the rate
of 4% for each 1,000 feet above sea level. Canada Only - Boilers may be used at high altitude by using a certified field conversion kit, resulting in a 10% de-rate.
+ Heating Capacity based on D.O.E. (Department of Energy) test procedure.
New york City mEA Number 484-84-E Vol. IV.
The Ratings marked "Net I=B=R Ratings" indicate the amount of re-
maining heat input that can be used to heat the radiation or terminal
units. The Net I=B=R Ratings shown are based on an allowance of
1.15 in accordance with the factors shown on the I=B=R Standard as
published by The Hydronics Institute.

INSTALLATION INSTruCTIONS

These instructions must be affixed on or adjacent to the boiler.

BOILEr rATINgS ANd CApACITIES

Table 1 -RATINGS NATURAL AND PROPANE GASES
AGA/CGA
Input *MBH
2
42.5
3
75.0
4
112.5
5
150.0
6
187.5
7
225.0
Improper installation, adjustment, alteration, service or
!
maintenance can cause injury or property damage. Refer
to this manual. For assistance or information consult a
qualified installer, service agency or the gas supplier.
Heating
Net IBR
Capacity *MBH+
Rating *MBH
36
31
63
55
94
82
125
109
155
135
186
162
Selection of boiler size should be based upon "Net I=B=R Rating"
being equal to or greater than the calculated heat loss of the building.
The manufacturer should be consulted before selecting a boiler for
installations having unusual piping and pickup requirements.
3
WARNING
DESIGN CERTIFIED FOR
NATURAL AND PROPANE GAS
Vent Diameter (Inches)
Width
A
To Chimney
(Category I)
11
4
14-1/4
4
17-1/2
4
20-3/4
4
24
4
27-1/4
4
H
Horizontal Vent
(Category III)
3
3
3
3
4
4