Advertisement

Quick Links

The Cancun
Ceiling Fans
-220
FP8009OB
Net Weight 11.50 kgs
FP8011OB-220
Net Weight 13.50 kgs
Model Nos. FP8009OB-220 | FP8011OB-220
OWNER'S MANUAL
READ AND SAVE THESE INSTRUCTIONS

Advertisement

Table of Contents
loading

Summary of Contents for Fanimation Cancun FP8009OB-220

  • Page 1 ™ The Cancun Ceiling Fans -220 FP8009OB Net Weight 11.50 kgs FP8011OB-220 Net Weight 13.50 kgs Model Nos. FP8009OB-220 | FP8011OB-220 OWNER’S MANUAL READ AND SAVE THESE INSTRUCTIONS...
  • Page 2: Table Of Contents

    Fanimation. 7. Fanimation reserves the right to modify or discontinue any product at any time and may substitute any part under this warranty. 8. Under no circumstances may a fan be returned without prior authorization from Fanimation. The receipt of purchase must ac- company authorized returns and must be sent freight prepaid to Fanimation.
  • Page 3: Unpacking Instructions

    Downrod/Hanger Ball – Four wire connectors Fanimation. Substitution of parts or accessories not Assembly – Chain fob/coupler designated for use with this product by Fanimation could • Ceiling Canopy – Balance Kit result in personal injury or property damage. Contact •...
  • Page 4: Energy Efficient Use Of Ceiling Fans

    8 - 9 feet above the floor for optimal airflow. Consult your down into the occupied space. Remember to adjust your Fanimation Retailer for optional mounting accessories. thermostat when using your ceiling fan - additional energy and dollar savings could be realized with this simple step! Turn Off When Not in the Room Ceiling fans cool people, not rooms.
  • Page 5: How To Assemble Your Ceiling Fan

    How to Assemble Your Ceiling Fan 1. Remove the hanger ball portion from the downrod/ hanger ball assembly by loosening the set screw in the hanger ball until the ball falls freely down the downrod. Remove the pin from the downrod, then remove the DOWNROD hanger ball.
  • Page 6: How To Hang Your Ceiling Fan

    How to Assemble Your Ceiling Fan (continued) 6. Cut off excess lead wire approximately 6 to 9 inches above top of the top of the downrod. Strip insulation off 1/2 inch from the end of each lead wire. (Figure 6) NOTE: All set screws must be checked, and retightened where necessary, before installation.
  • Page 7: How To Wire Your Ceiling Fan

    How to Wire Your Ceiling Fan If you feel that you do not have enough electrical wiring knowledge or experience, have your fan installed by a licensed electrician. WARNING To avoid possible fire or shock, be sure electricity is turned off at the main fuse box before wiring. MAIN FUSE BOX (Figure 11) ▲WARNING...
  • Page 8: How To Assemble The Blades

    Installing the Canopy Housing (continued) 2. Securely attach and tighten the canopy screw cover over the shoulder screws in the hanger bracket utilizing the key slot twist-lock feature. (Figure 14) CANOPY SCREW COVER Figure 14 How to Assemble the Blades 1.
  • Page 9: Housing/Adapter Switch Cup Assembly

    Housing/Adapter Switch Cup Assembly 1. Disassemble the housing adapter switch cup assembly FP8009OB-220 FP80011OB-220 by removing three screws. (Figure 18) HOUSING/ADAPTER HOUSING/ADAPTER SWITCH CUP SWITCH CUP WITH LIGHT FITTER Figure 18 2. Remove one of the three screws in the support bracket.
  • Page 10: Light Kit Assembly-Fp8011Ob-220 Only

    Light Kit Assembly—FP8011OB-220 ONLY 1. Install included bulbs into each of the three sockets. (Figure 22) CAUTION To reduce the risk of electric shock, disconnect the electrical supply circuit to the fan before installing light kit. Use only with light kits marked suitable for use in Damp Locations.
  • Page 11: Pull Chain Operating Instructions

    Pull Chain Operating Instructions 1. Restore electrical power to the outlet box by turning the electricity on at the main fuse box. (Figure 25) MAIN FUSE BOX Figure 25 2. Check the operation of the fan by gently pulling on FP8009OB-220 FP80011OB-220 the fan speed pull chain.
  • Page 12: Parts List

    Parts List Models FP8009OB-220 & FP8011OB-220 FP8011OB-220 FP8009OB-220 Ref. # Description Hanger Bracket Assembly AP255BL-220 AP255BL-220 Downrod/Hanger Ball Assembly: ADR1-45OB ADR1-45OB Ceiling Canopy PG165OB PG165OB Canopy Screw Cover AP260OB AP260OB Motor Coupling Cover AP1115OB AP1115OB Fan Motor Assembly AMA8009OB-220 AMA8011OB-220 Adapter Switch Cup Assembly AP800901OB-220 —...
  • Page 13: Exploded-View Drawing

    FP8009OB-220 & FP8011OB-220 Exploded-View FP8009OB-220 ONLY FP8011OB-220 ONLY NOTE: The illustration shown is not to scale or its actual configuration may vary...
  • Page 14: Trouble Shooting

    Trouble Shooting WARNING For your own safety turn off power at fuse box or circuit breaker before trouble shooting your fan. Trouble Probable Cause Suggested Remedy 1. Fuse or circuit breaker blown. 1. Check main and branch circuit fuses or circuit breakers.
  • Page 16 10983 Bennett Parkway Zionsville, IN 46077 Toll Free (888) 567-2055 FAX (866) 482-5215 Outside U.S. call (317) 733-4113 Visit Our Website @ www.fanimation.com Copyright 2010 Fanimation 2010/07...

This manual is also suitable for:

Cancun fp8011ob-220

Table of Contents