Voltage below 12.5V indicates a discharged
condition; 12V or less is dead.
Voltage above 13V typically indicates that
the battery is being charged by the inverter
charger system.
Battery Voltage Check
One Place Panel
To get an accurate reading;
1. Both the chassis engine and the auxiliary
generator engine must be shut off.
2. An interior light should be turned on to pro-
vide a small load which draws off the battery
surface charge.
The "Pilot Out" light will glow for about 10-
15 seconds after the water heater switch is turned
on, then it will go off. The "Heater On" light will
remain lit.
If the "Pilot Out" light comes on during nor-
mal operation, it means that the burner has gone
into "lockout" mode. Turn the switch off for
about 5 minutes, then turn back on.
GAS/ELECTRIC

WATER HEATER

(with Motor Aid water heating
system)
Capacity: 10 gal.
APPLIANCES & INTERIOR FEATURES
The water heater has a dual power feature. It
can operate from LP gas or 110-volt house cur-
rent; or it can use both at the same time for
quicker recovery at times when you are using a
lot of hot water.
Read the Atwood Gas Water Heater Installa-
tion and Operation Manual for complete Safety
Warnings, Operating Instructions and Mainte-
nance Information before operating the water
heater.
Be sure the water heater is filled with
water before starting either electric or LP
operation. To fill the water heater, turn the
Water Pump switch on and open a hot water fau-
cet anywhere in the coach. When water begins to
flow steadily from the faucet, the water heater is
full.
For Electric Operation: Turn on the Water
Heater electric element switch. The shoreline
must be connected for electric operation.
Electric Water Heater Switch
For LP Gas Operation: Press the Water
Heater switch on the Monitor Panel. The "Pilot
Out" light will glow for about 10-15 seconds,
then it will go out and the "Heater On" light will
glow. If the "Pilot Out" light comes on during
LP operation, it means that the burner has gone
into "lockout" mode and must be restarted. If
this happens, turn the Water Heater switch off
for about 5 minutes, then turn it back on. See the
Atwood user's guide in your Owners InfoCase
for further information.