SECTION 10
STORING YOUR MOTOR HOME
· Place a container beneath the filter base
and lower the valve handle to drain any
water remaining in the filter lines.
5. Install the antifreeze diverter plug:
· Raise the valve handle on the filter base.
· Hold the diverter by the support bar as
shown and guide it up into the center of
the filter base with bar end approximately
centered in colored ring cutout.
· Push the diverter up into the base as far as
possible and turn it clockwise approxi-
mately a quarter-turn until it stops.
· Lower valve handle to lock the diverter
plug in place.
NOTE:
Before using again the following
spring:
10-2
Flush out the system with the diverter in
place.
After the system has been thoroughly flushed,
remove the diverter and store for future use.
The diverter plug is intended for winteriza-
tion only.
Install a new water filter cartridge.
If your coach is equipped with the refrigera-
tor ice maker option, the ice maker water
lines must also be drained. See "Winterizing
the Ice Maker" in the refrigerator users
guide in your InfoCase.
6. Turn the Water Pump switch ON to allow it
to operate until you are done draining all fau-
cets and toilet.
7. Open all faucets and shower head valves,
including exterior shower.
8. Operate the toilet flush lever and hold until
water stops flowing in the toilet. Then turn
water pump switch OFF.
9. Turn off the water heater power switch
before draining the water heater tank to
avoid damage to the heating element.
Drain the water heater by removing the plug
from the base of the water heater tank, acces-
sible from the outside of the coach.
(Requires socket and ratchet.) Also open the
Pressure-Temperature relief valve at the top
right portion of the tank to prevent air lock-
ing in the tank while draining.