Sinclair GSH-60IRA series Operational Manual page 43

Air-to-water heat pump installation manual
Hide thumbs Also See for GSH-60IRA series:
Table of Contents

Advertisement

CN66、CN67
communication cable 2 pin B,3pinA
communication cable: 1 pin earthed,2 pin B,3 pin A,4 pin+12power supply;
CN65
It can not be used for communication between outdoor unit and indoor unit;
pipe electric expansion valve
FA
1-4 pin:driving impulse output;5 pin:+12V;
signal input of pressure sensor
H-PRESS
1 pin:GND;2 pin:signal input;3 pin:+5V
18.1.2
GSH-120ERA, GSH-140ERA, GSH-160ERA
silk screen
AC-L
N
L1-1
L2-1
L1-2
U
V
W
DC_MOTOR1
DC_MOTOR2
4V1
AIR-TO-WATER HEAT PUMP INSTALLATION MANUAL
specification
live wire input of power supply, red
Neutral line input of power supply ( PFC blue inductive wire)
PFC brown inductive wire
PFC yellow inductive wire
PFC white inductive wire
U-phase of compressor
V-phase of compressor
W-phase of compressor
DC fan
1 pin:strong power supply;3 pin:fan GND;4 pin:+15V;
5 pin:control signal;6 pin:feedback signal;
DC fan
1 pin:strong power supply;3 pin:fan GND;4 pin:+15V;
5 pin:control signal;6 pin:feedback signal;
4-way valve
41
blue

Advertisement