AIR-TO-WATER HEAT PUMP INSTALLATION MANUAL
8.2.3 Precautions on Installation of Outdoor Unit
When moving outdoor unit, it is necessary to adopt 2 pieces of long enough rope to hand
the unit from 4 directions. Included angle between the rope when hanging and moving
must be 40°below to prevent center of the unit from moving.
Adopt M12 bolts components to tighten feet and under frame when installing.
Outdoor unit should be installed on concrete base that is 10cm height.
Requirements on installation space dimension of unit's bodies are shown in following
drawing.
Outdoor unit must be lifted by using designated lifting hole. Take care to protect the unit
during lift. To avoid rusting, do not knock the metal parts.