Uart"A; Uart"B" / Lin "A - Fujitsu SK-91465X-100PMC User Manual

Table of Contents

Advertisement

3.4 UART"A"

One RS232-transceiver (U5, X6) can be connected to one of the microcontroller's UART
interfaces.
JP26, JP29
connect UART 3 to the RS232-transceiver (U1, X3)
JP24
Some programs (e.g. Terminals) need a connection between CTS and RTS
Jumper
JP26 (UART"A"RxD)
JP29 (UART"A"TxD)
JP24 (RTS-CTS)
Default: grey

3.5 UART"B" / LIN "A"

One RS232-transceiver (U7) or one LIN-transceiver (U6) can be connected to one of the
microcontroller's UART interfaces. Connect to D-Sub X8 corresponding RS232 or LIN cable.
By default RS232 is selected to X8.
JP42 Selects if RS232 or LIN is connected to SIN7 of MCU
JP44 Selects if RS232 or LIN is connected to SOT7 of MCU
JP40 Selects if UARTB or LINA is connected to pin2 of X8
JP49 Some programs (e.g. Terminals) need a connection between CTS and RTS
JP37 Enable LIN-Transceiver
JP32 Selects LIN Master mode
JP38 Connects Vs (Pin 1 of X8) to Vin
Jumper
JP42
(UART B / LIN A)
JP44
(UART B / LIN A)
JP40
(X8 pin2)
JP49
(RTS-CTS)
© Fujitsu Microelectronics Europe GmbH
SK-91465X-100PMC User Guide
Chapter 3 Jumpers and Switches
Setting
Description
Closed
SIN4 of the MCU is connected to UART"A"
Open
SIN4 of the MCU is not connected to UART"A"
Closed
SOT4 of the MCU is connected to UART"A"
Open
SOT4 of the MCU is not connected to UART"A"
Closed
RTS and CTS of X6 are connected
Open
RTS and CTS of X6 are not connected
Table 3-5: UART "A" jumper settings
Setting
Description
1-2
SIN7 of the MCU is connected to U7 (RS232)
2-3
SIN7 of the MCU is connected to U6 (LIN)
1-2
SOT7 of the MCU is connected to U7 (RS232)
2-3
SOT7 of the MCU is connected to U6 (LIN)
1-2
BUS Signal (LINA) is connected to pin2 of X8
2-3
Tx Signal (UARTB) is connected to pin2 of X8
Closed
RTS and CTS of X8 are connected
Open
RTS and CTS of X8 are not connected
- 17 -