3 Jumpers and Switches

This chapter describes all jumpers and switches that can be modified on the evaluation
board. The default setting (MB91F465XA Series) is shown with a grey shaded area.

3.1 Operating Mode (S1)

The DIP-switch S1 is used to set the operating mode of the MCU. Ensure that the mode pin
settings correspond to the operation-mode of the application. For more detailed information
please check the Hardware-Manual of the microcontroller.
DIP switch
S1/1 (MD0)
S1/2 (MD1)
S1/3 (MD2)
S1/4
Default: grey
Dip-Switch S2
(default setting)
© Fujitsu Microelectronics Europe GmbH
SK-91465X-100PMC User Guide
Chapter 3 Jumpers and Switches
Setting
ON (closed)
OFF (open)
ON (closed)
OFF (open)
ON (closed)
OFF (open)
not connected
Table 3-1: MCU operating mode
MD0 MD1 MD2 nc
1
2
Figure 3-1: MCU Mode Switch
- 13 -
Logical value
1 (high)
0 (low)
1 (high)
0 (low)
1 (high)
0 (low)
ON
OFF
3
4
UG-910056-11