Technical Specifi Cations - Optimus UMX-02/0 Operating Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

ENGLISH
14. Click on the Program Flash button and start the download.
When
the
succefully Written to device" appears in green color.
15. Click on Exit button to close the Flash Development Toolkit
Basic application.
Eng
16. Disconnect the power supply from the UMX-
02/0.
17. Disconnect the download cable.
18. Confi gure the front dipswitch in NORMAL
MODE position.
19. Connect the power supply once again.
To test that the fi rmware version is properly updadted, press CANCEL button and the UMX-02/0 LCD
display will show the new version.
5. Technical specifi cations
Power supply
Consumption
Capacity
Audio channels
Communication system
Finishes
Transmission speed
Weight
Dimensions
56
UMX-02/0
download
completes
the
message
"Image
Figure 17
NORMAL MODE
RS232 CONFIGURATION
FIRMWARE DOWNLOAD MODE
Figure 18
24 V.d.c.
560 mA (without cards)
10 cards
16
RS-485 by means of RJ45 connector
CSMA/CD protocol
Front panel: Iron black painted
Cover: Black Skinplate
9600 bps
5,8 Kg.
482,6 x 88,6 x 300 mm
ON
OFF
1 2 3 4 5
6
7
8
ON
OFF
1 2 3 4 5
6
7
8
ON
OFF
1 2 3 4 5
6
7
8
UMX-02/0 v1.0