Capacity Table; Combinations - Fujitsu AUU9RLF Design & Technical Manual

Hide thumbs Also See for AUU9RLF:
Table of Contents

Advertisement

5.

CAPACITY TABLE

5-1.

COMBINATIONS

MODEL : AOU18RLXFZ
Cooling
Combination of indoor unit
indoor unit
Room 1 Room 2
Total
7
7
14
Non-ducted
7
9
16
Non-ducted
7
9
16
7
12
19
Non-ducted
7
12
19
9
9
18
Non-ducted
9
9
18
9
12
21
Non-ducted
9
12
21
Heating
Combination of indoor unit
indoor unit
Room 1 Room 2
Total
7
7
14
Non-ducted
7
9
16
Non-ducted
7
9
16
7
12
19
Non-ducted
7
12
19
9
9
18
Non-ducted
9
9
18
9
12
21
Non-ducted
9
12
21
Note:
1. Specifications are based on the following conditions.
Power source of specifications : 230V
Pipe length : 24.6ft.(7.5m), Height difference : 0 ft.(0m) [Outdoor unit - Indoor unit]
Cooling: Indoor temperature of 80°F(26.7°C)DB / 67°F(19.4°C)WB,and outdoor temperature of 95°F(35°C)DB/75°F(23.9°C)WB.
Heating: Indoor temperature of 70°F(21.1°C)DB / 60°F(15.6°C)WB,and outdoor temperature of 47°F(8.3°C)DB/43°F(6.1°C)WB.
2. The total ability of connected a indoor unit is up to 21,000BTU from 14,000BTU.
3. Non-Ducted system combinations input are based on ASU wall mount models. The input of combinations including AUU cassette models may be a
little higher.
4. Ducted system combinations capacities are based on ARU slim duct units with the exception of 7,000BTU models are based on ASU wall mount
models.
Rated capacity
Maximum capacity
for each indoor unit
for each indoor unit
Type of
[kBTU/h]
Room 1
Room 2
Room 1
7.05
7.05
8.70
7.09
9.11
8.66
ducted
7.09
9.11
8.66
6.63
11.37
7.74
ducted
6.63
11.37
7.74
9.00
9.00
10.50
ducted
9.00
9.00
10.50
7.71
10.29
9.00
ducted
7.71
10.29
9.00
Rated capacity
Maximum capacity
for each indoor unit
for each indoor unit
Type of
[kBTU/h]
Room 1
Room 2
Room 1
9.20
9.20
10.35
8.93
11.48
9.58
ducted
8.93
11.48
9.58
8.11
13.89
8.99
ducted
8.11
13.89
8.99
11.00
11.00
12.20
ducted
11.00
11.00
12.20
9.43
12.57
10.46
ducted
9.43
12.57
10.46
- (02 - 05) -
Total capacity [kBTU/h]
[kBTU/h]
Room 2
Min
Rated
8.70
6.10
14.10
17.40
11.14
6.10
16.20
19.80
11.14
6.10
16.20
19.80
13.26
6.10
18.00
21.00
13.26
6.10
18.00
21.00
10.50
6.10
18.00
21.00
10.50
6.10
18.00
21.00
12.00
6.10
18.00
21.00
12.00
6.10
18.00
21.00
Total capacity [kBTU/h]
[kBTU/h]
Room 2
Min
Rated
10.35
6.80
18.40
20.70
12.32
6.80
20.40
21.90
12.32
6.80
20.40
21.90
15.41
6.80
22.00
24.40
15.41
6.80
22.00
24.40
12.20
6.80
22.00
24.40
12.20
6.80
22.00
24.40
13.94
6.80
22.00
24.40
13.94
6.80
22.00
24.40
Input power [kW]
Max
Min
Rated
Max
0.50
1.30
1.64
0.50
1.44
1.81
0.50
1.49
1.86
0.50
1.43
2.06
0.50
1.48
2.11
0.50
1.44
2.06
0.50
1.49
2.14
0.50
1.44
2.06
0.50
1.49
2.14
Input power [kW]
Max
Min
Rated
Max
0.52
1.50
1.97
0.52
1.77
1.92
0.52
1.73
1.90
0.52
1.87
2.10
0.52
1.83
2.08
0.52
1.87
2.10
0.52
1.83
2.08
0.52
1.88
2.10
0.52
1.84
2.08