10. FUEL SYSTEM
Inspection
Check the reed valve for damage and its reed
strength.
Check the reed valve seat for crack, damage
and the clearance between the seat and the
valve.
Replace reed valve if necessary.
Caution
Do not bend the reed valve stopper.
Otherwise, it will cause its strength insufficient
and rough engine running. If the reed valve
or its seat is damaged, replace with a set.
Installation
Install in the reverse order of removal
procedures.
Check for leaking after installed.

Air Cleaner

Removal/Installation
Loosen connection hose band.
Remove 2 bolts and then remove the air
cleaner.
Install in the reverse order of removal
procedures.