6. ALTERNATOR
Disconnect alternator wire connector and pulse
generator connector.
Remove the pulse generator and alternator four
bolts, and then take out the alternator assembly.
Caution
Care to be taken for not damaging the alternator
coil.
Alternator Installation
Install the alternator assembly.
Connect the alternator connector.
Caution
Connect the alternator wire harness properly
and then clip the harness with clipper.
Install the woodruff key onto the crankshaft
groove.
Caution
Clean dirt and metal pieces inside the
flywheel.
Make sure that there is no foreign material
inside the flywheel.
Install the flywheel
Tighten the flywheel 10 mm nut.
Torque value: 3.8kgf-m
Install the removed parts in reverse order of
removal procedures.
Start engine and check its ignition timing.
6-4