Note: If diagnostic error messages appear that are not listed in the following tables,
Code
Function
001
Core system
Failed
005
Video port
011
Serial port
014
Parallel port
015
USB interface
Aborted
Failed
020
PCI interface
Failed
030
SCSI interface Failed
035
ServeRAID
Aborted
make sure that your server has the latest levels of BIOS, Advanced System
Management Processor, ServeRAID, and diagnostics microcode installed.
Result
Processor board, ECC Test
System board
Processor and system boards
Integrated serial port
Integrated parallel port
Can NOT test USB interface while it is in use.
Note: If you have a USB keyboard or mouse
attached, you cannot run the diagnostic
program for the USB interface.
System board
System board
Tab on PCI Hot Swap slot #n is bad
(where n is the number of the failing PCI slot)
Note: For normal operation, the Power LED for
the hot-plug PCI slot will be on and the
Attention Led will be off.
SCSI adapter in slot n failed register/counter/
power test
(where n is the slot number of the failing adapter)
SCSI controller on system board failed
register/counter/power test
Test setup error: No ServeRAID adapter found
on system board or PCI bus
Text message
Action
Call for service.
1. Turn off the
server.
2. Replace the USB
keyboard and
mouse with a
standard
keyboard and
mouse.
3. Turn on the
server.
4. Run the
diagnostic test
again.
Call for service.
Call for service.
Make sure the tab and
latch on hot-plug PCI
slot n are closed
correctly.
If the problem persists,
call for service.
Refer to the
information provided
with the adapter for
instructions.
If the problem persists,
call for service.
Call for service.
Make sure the
ServeRAID adapter is
properly installed.
If the problem
remains, replace the
ServeRAID adapter.
If the problem persists,
call for service.
Chapter 7. Solving problems