9 OPERATION RANGE

The applicable voltage range for each unit is given in "the following table". The working voltage among the three phases
must be balanced within 3% deviation from each voltage at the compressor terminals. The starting voltage must be higher
than 85% of the rated voltage.
Power Supply
Model
Unit Main Power
CU-
Phase, Volts
W24BBP5
1~220
W28BBP5
1~230
V24BBP5
1~240
V28BBP5
Indoor and Outdoor Temperature
Cooling only type
Model 50Hz ... V24BBP5 (8), V28BBP5 (8), V34BBP8, V43BBP8
Operating
Cooling
Heat pump type
Model 50Hz ... W24BBP5, W28BBP5 (8), W34BBP8, W43BBP8
Operating
Cooling
Heating
Applicable Voltage
Hz
Maximum
Minimum
50
242
198
50
253
207
50
264
216
Hz
Indoor Temp. (D.B./W.B.) (°C)
Maximum
50
32/23
Hz
Indoor Temp. (D.B./W.B.) (°C)
Maximum
50
32/23
50
27/-
Model
Unit Main Power
CU-
Phase, Volts
W28BBP8
3N~380
W34BBP8
3N~400
W43BBP8
3N~415
V24BBP8
V28BBP8
V34BBP8
V43BBP8
Minimum
21/15
Minimum
21/15
16/-
47
Applicable Voltage
Hz
Maximum
Minimum
50
418
50
440
50
457
Outdoor Temp. (D.B./W.B.) (°C)
Maximum
Minimum
43/-
-5/-
Outdoor Temp. (D.B./W.B.) (°C)
Maximum
Minimum
43/-
-5/-
24/18
-10/-
342
360
374