11 OPERATING CHARACTERISTIC

HEAT PUMP MODEL
Model
Main Power
Source
Voltage
(V)
CS-W24BD2P
220
CU-W24BBP5
230
240
CS-W28BD2P
220
CU-W28BBP5
230
240
CS-W28BD2P
380
CU-W28BBP8
400
415
CS-W34BD2P
380
CU-W34BBP8
400
415
CS-W43BD2P
380
CU-W43BBP8
400
415
COOLING ONLY MODEL
CS-W24BD2P
220
CU-V24BBP5
230
240
CS-W24BD2P
380
CU-V24BBP8
400
415
CS-W28BD2P
220
CU-V28BBP5
230
240
CS-W28BD2P
380
CU-V28BBP8
400
415
CS-W34BD2P
380
CU-V34BBP8
400
415
CS-W43BD2P
380
CU-V43BBP8
400
415
Legend:
S.C.: Starting Current
R.C.: Running Current
IPT: Power Consumption
Compressor Motor
Frequency
S.C.
R.C.(A)
(Hz)
(A)
COOL / HEAT COOL / HEAT
50
64
10.5 / 10.7
50
66
9.9 / 10.1
50
68
9.5 / 9.6
50
68
11.9 / 12.6
50
70
11.2 / 11.9
50
72
11.2 / 11.4
50
28
4.19 / 4.09
50
29
4.18 / 4.08
50
30
4.17 / 4.07
50
39
3.94 / 4.24
50
41
3.90 / 4.20
50
42
3.86 / 4.16
50
58
6.91 / 7.11
50
58
6.90 / 7.10
50
58
6.90 / 7.10
50
64
10.5
50
66
9.9
50
68
9.5
50
27
2.85
50
28
2.79
50
29
2.75
50
68
12.7
50
70
12.1
50
72
12.1
50
28
3.37
50
29
3.33
50
30
3.30
50
39
5.45
50
41
5.43
50
42
5.42
50
58
6.91
50
58
6.90
50
58
6.90
Indoor Unit
Fan Motor
IPT(kW)
R.C.
IPT
(A)
(kW)
2.31 / 2.35
0.79
0.15
2.29 / 2.33
0.84
0.16
2.28 / 2.32
0.87
0.17
2.60 / 2.76
0.77
0.16
2.58 / 2.74
0.80
0.17
2.57 / 2.73
0.82
0.18
2.46 / 2.60
0.77
0.16
2.44 / 2.58
0.80
0.17
2.43 / 2.57
0.82
0.18
3.39 / 3.58
1.35
0.29
3.36 / 3.55
1.36
0.31
3.33 / 3.52
1.37
0.32
3.91 / 4.08
1.67
0.36
3.88 / 4.05
1.67
0.38
3.85 / 4.02
1.66
0.39
2.31
0.79
0.15
2.29
0.84
0.16
2.28
0.87
0.17
2.17
0.79
0.15
2.15
0.84
0.16
2.14
0.87
0.17
2.60
0.77
0.16
2.58
0.80
0.17
2.57
0.82
0.18
2.46
0.77
0.16
2.44
0.80
0.17
2.43
0.82
0.18
3.39
1.35
0.29
3.36
1.36
0.31
3.33
1.37
0.32
3.91
1.67
0.36
3.88
1.67
0.38
3.85
1.66
0.39
50
Outdoor Unit
Electrical Data (50Hz)
Fan Motor
R.C
R.C.
IPT
(A)
(A)
(kW) COOL / HEAT COOL / HEAT
0.46
0.10
11.7 / 11.9
0.47
0.11
11.2 / 11.4
0.48
0.11
10.8 / 10.9
0.46
0.10
13.1 / 13.8
0.47
0.11
12.5 / 13.2
0.48
0.11
12.5 / 12.7
0.46
0.10
4.60 / 4.50
0.47
0.11
4.60 / 4.50
0.48
0.11
4.60 / 4.50
0.91
0.20
6.20 / 6.50
0.94
0.21
6.20 / 6.50
0.97
0.23
6.20 / 6.50
0.99
0.22
7.80 / 8.00
1.02
0.23
7.80 / 8.00
1.04
0.25
7.80 / 8.00
0.46
0.10
11.7
0.47
0.11
11.2
0.48
0.11
10.8
0.46
0.10
4.10
0.47
0.11
4.10
0.48
0.11
4.10
0.46
0.10
13.1
0.47
0.11
12.5
0.48
0.11
12.5
0.46
0.10
4.60
0.47
0.11
4.60
0.48
0.11
4.60
0.91
0.20
6.20
0.94
0.21
6.20
0.97
0.23
6.20
0.99
0.22
7.80
1.02
0.23
7.80
1.04
0.25
7.80
IPT
(kW)
2.56 / 2.60
2.56 / 2.60
2.56 / 2.60
2.86 / 3.02
2.86 / 3.02
2.86 / 3.02
2.72 / 2.86
2.72 / 2.86
2.72 / 2.86
3.88 / 4.07
3.88 / 4.07
3.88 / 4.07
4.49 / 4.66
4.49 / 4.66
4.49 / 4.66
2.56
2.56
2.56
2.42
2.42
2.42
2.86
2.86
2.86
2.72
2.72
2.72
3.88
3.88
3.88
4.49
4.49
4.49