DS6400 QUICK GUIDE
Ethernet Model
DS6400
T X+
1
T X-
2
RX+
3
n. c.
4
n. c.
5
RX-
6
n. c.
7
n. c.
8
n. c. = not connected
DeviceNet Model
When using DeviceNet, the Main serial interface is disabled and must not be physically
connected.
NOTE
Pin
Name
2
V+
5
CAN_L
1
SHIELD
4
CAN_H
3
V-
The power supplied on pin V+ and V- is used only to propagate power to the section of the
DeviceNet board directly connected to the Bus. It is completely isolated from the DS6400
power which must be supplied on pin 9, 13 and pin 23, 25 of the 26-pin Main/Aux connector.
NOTE
Profibus Model
Pin
Name
1
Shield
2
Free
3
B-LINE (RxD/TxD-P) Received/Transmitted Data-P
4
CNTR-P
5
DGND
6
+5 V
7
Free
8
A-LINE (RxD/TxD-N) Received/Transmitted Data
9
CNTR-N
8
RJ45 Modular Connector
HUB / SWITCH
1
2
3
4
5
6
7
8
5-pin DeviceNet Connector Pinout
Function
Supply voltage – positive pin
CAN bus data line – L
Shield
CAN bus data line – H
Supply voltage – negative pin
9-pin Profibus Connector
Function
Shield, Protective Ground resp. (optional)
Repeater Control Signal (optional, RS485 level)
Data Ground (M5V)
Voltage Plus (P5V)
Repeater Control Signal
1
RJ45 Female Connector
4
3
5
2
1
5-pin male DeviceNet Connector
5
9
9-pin female Profibus Connector
(white)
8
1
6

Advertisement

Table of Contents
loading