GENERAL VENTING REQUIREMENTS AND
GUIDELINES
MULTIVENTING OF DIRECT-VENT FURNACES
Figures 33 & 34: NOTE: WHEN VENTING MULTIPLE FURNACES IN CLOSE PROXIMITY, EACH FURNACE MUST
BE INDIVIDUALLY VENTED – NO COMMON VENTING IS PERMITTED. See Figures 33 & 34 for positioning of the
naces and the third and etc. Figure 33, (Detail A) below shows the necessary detail for the roof penetration on a stan-
terminations. When more than two furnaces are to be vented, there must be at least 4 feet between the first two fur-
TWO-PIPE VENTING
THROUGH ROOF
dard direct-vent vertical termination.
FIGURE 33
TWO FURNACE VENTING
TWO-PIPE VENTING
COMBUSTION
TWO PIPE VENTING THROUGH ROOF
AIR INTAKE
2" PVC
TERMINATIONS MORE THAN
24" ABOVE ROOF PENETRA-
SEE DETAIL
TION REQUIRE ADDITIONAL
"A"
SUPPORT.
COMBUSTION
AIR INTAKE
2" PVC
SEE DETAIL
"A"
TWO-PIPE VENTING
THROUGH WALL
TWO PIPE VENTING THROUGH WALL
TWO-PIPE VENTING
12"/31cm MIN. ABOVE
A
GRADE OR HIGHEST
8"/20cm
ANTICIPATED SNOW LEVEL.
CANADA: MUST CONFORM TO
MIN.
CSA B149.1-10, SECT. 8.14
DIRECT VENT VERTICAL TERMINATION DETAIL
12"/31cm MIN. ABOVE
GRADE OR HIGHEST
ANTICIPATED SNOW LEVEL.
8"/20cm
CANADA: MUST CONFORM TO
MIN.
48" MAX.
45" MAX.
CSA B149.1-10, SECT. 8.14
(122 cm)
(114 cm)
3" MIN.
*
(8 cm)
*3" (8cm) minimum only if no snow accumulation is anticipated.
66
3"/8cm
MAX.
NOTE: IF 3 Ø
THROUGH ROOF
VENTING IS
USED, BOTH
PIPES (INTAKE
AND EX-
TERMINATIONS
HAUST) MUST
MUST BE GREATER
BE REDUCED
THAN 8" APART.
TO 2 Ø
3" (8cm) MIN.
BEFORE
12" (32cm) MAX.
PENETRATING
ROOF.
See
A
ST-A1194-22
THROUGH WALL
ST-A1194-21
12" (31cm) U.S.
36" MAX.
CANADA: TERMINATIONS
(91 cm)
MUST CONFORM TO
CSA B149.1-10, SECT. 8.14
NOTE: IF 3 Ø
VENTING IS USED,
BOTH PIPES (INTAKE
AND EXHAUST) MUST
BE REDUCED TO 2 Ø
BEFORE PENETRATING
ROOF.
ST-A1194-18
DETAIL A
FIGURE 34
TWO FURNACE VENTING WITH CONCENTRIC VENTING
CONCENTRIC VENTING THROUGH ROOF
CONCENTRIC VENTING THROUGH WALL
*
CANADA: TERMINATION MUST CONFORM TO CSA B149.1-10,
SECT 8.14.
DETAIL A
A
➀ Terminations must be greater than 8" apart.
Terminations must be less than 24" apart or greater than
36" apart.
Each additional termination must be greater than 48" from
the previous termination.
A
SEE
A
SEE
MINIMUM 12"/31cm IN
U.S. ABOVE AVERAGE
SNOW ACCUMULATION.
MAXIMUM OF 24"/61cm
ABOVE ROOF.*
MINIMUM 12"/31cm IN
U.S. ABOVE AVERAGE
SNOW ACCUMULATION.
MAXIMUM OF 24"/61cm
ABOVE ROOF.*
6' (1.8m) MINIMUM
10' (3m) RECOMMENDED
MINIMUM 12"/31cm
*
ABOVE GRADE IN U.S.
6' (1.8m) MINIMUM
10' (3m) RECOMMENDED
MINIMUM 12"/31cm
*
ABOVE GRADE IN U.S.
A
SEE
A
SEE
2 FURNACES
3rd OR MORE FURNACES
ST-A1194-22