Horizontal Right With Right Vent - Rheem *96V series Installation Instructions Manual

4 position condensing two-stage, communicating gas furnaces w/ecm blower
Table of Contents

Advertisement

HORIZONTAL RIGHT / RIGHT VENT
AIRFLOW
PARTS NEEDED:
FROM PARTS BAG
(PROVIDED WITH UNIT)
INTAKE
COUPLING
AND NUT
TOOLS/MATERIALS NEEDED:
DRILL
PLIERS
1/8" DRILL BIT
FLAT HEAD SCREWDRIVER
NOTE: THESE CONVERSION INSTRUCTIONS ARE INTENTIONALLY GENERIC, SOME PARTS MAY BE DIFFERENT IN YOUR FURNACE
NOTE: STEPS 1- 5 SHOWN WITH FURNACE IN "AS SHIPPED CONDITION"
1
1a - REMOVE TRAP AND HOSES
(NOTE: TO REMOVE TRAP, REMOVE (2) SCREWS
AND PULL STRAIGHT OUT)
1b - INSTALL INTAKE COUPLING IN TOP PLATE
AS SHOWN.
1a
28
PARTS NEEDED FOR THIS CONVERSION REQUIRE ITEMS
PARTS NEEDED FOR THIS CONVERSION REQUIRE ITEMS
!
FROM THE PARTS BAG AND CONVERSION KIT RXGY-CK.
FROM THE PARTS BAG AND CONVERSION KIT RXGY-CK.
YOU MUST HAVE THE PARTS OUTLINED BELOW BEFORE PROCEEDING.
YOU MUST HAVE THE PARTS OUTLINED BELOW BEFORE PROCEEDING.
FROM CONVERSION KIT RXGY-CK
1/2" DRAIN
1/2" DRAIN
HOSE E
5/16 HEX HEAD DRIVER
1/4" HEX HEAD DRIVER
1b
HOSE "D" (DISCARD)
VENT HOSE (DISCARD)
CONDENSATE
TRAP GASKET
HOSE F
.559 DRAIN PLUG
2
2a - RELOCATE 1/2" VINYL CAP (YELLOW) ON THE
INDUCER COUPLING
2b - RELOCATE THE .403" DRAIN PLUG IN THE
COLLECTOR BOX.
2c - RELOCATE 1/4" VINYL CAP (YELLOW) ON
COLLECTOR BOX VENT TAP.
(X3)
1/4" BLACK
#8 X 1/2"
VENT TUBE
SCREW
MOVE
2c
MOVE
2b
MOVE
2a
ST-A1194-32-01