Insert Tools, Accessories; Technical Data; Pda 50/51/52 Target Plate; Pda 71 Measuring Extension - Hilti PD 42 Operating Instructions Manual

Table of Contents

Advertisement

2.12 PDA 50 / 51 / 52 target plate
The PDA 50 target plate is made of durable plastic with a special reflective coating. Use of the target plate is
recommended at distances greater than 10 m in poor light conditions.
The PDA 51 target plate has no reflective coating and its use is recommended in poor light conditions and at short
distances. The PDA 52 target plate is equipped with the same reflective coating as the PDA 50 but is considerably
larger in size (A4 format, 210 x 297 mm). This makes it much easier to aim the tool at the target plate over long
distances.
NOTE
For reliable distance measurements, care should be taken to ensure that the laser beam strikes the target plate at
right angles as far as possible. The laser spot on the target plate and the measuring reference point (starting point)
may otherwise be in different planes (parallax error).
NOTE
When the target plate is used and very high accuracy is required, 1.2 mm should be added to the measurement
obtained.

2.13 PDA 71 measuring extension

The measuring extension is made from aluminium and is equipped with a non-conductive plastic grip. The screw on
the measuring extension should be screwed into the threaded bush on the rear contact surface of the PD 42. When
the measuring extension is screwed onto the tool, the rear reference is then relocated to the tip of the measuring
extension, i.e. the rear reference is extended by 1270 mm (50 inches).

3 Insert tools, accessories

Designation
Target plate
Target plate
Target plate
Measuring extension
Designation
Hand strap
Soft pouch
Laser visibility glasses

4 Technical data

Right of technical changes reserved.
Technical data
Power supply
Battery condition check
Measuring range
Typical measuring range without target plate
Accuracy
Smallest unit displayed
Description
PDA 50
PDA 51
PDA 52
PDA 71
Description
PDA 60
PDA 65
PUA 60
Values
3V DC AA-size batteries
Battery condition indicator with 4 segments show-
ing 100%, 75%, 50%, 25% charge : No segments
shown: The batteries are exhausted
0.05...200 m
Drywall panel, white: 100 m
Concrete, dry: 70 m
Brick, dry: 50 m
Typically ±1.0 mm for single and continuous measure-
ment
1 mm
en
25

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents