Drilling a Hole in the Wall

Drill a hole of 70mm in diameter to the outside.
The drilling should be done at a distance of less than
150mm from the floor facing the indoor unit.

Drain Hose

Extend the drain hose to the drain hose connected to
the drain pan, and fix it with the tape or a cable-tie to
prevent separation. Then make a covering of it so
that water cannot flow outwardly.
Piping Material
Insulator
CAUTION
1. As the draining is of natural drain type, make the drain hose direct downward.
2. If there is any foreign substance in the drain plate, it may clog the drain pipe. Therefore, be sure to
remove the foreign substance inside after installation.
3. After completion of installation, be sure to pour water into the drain pan, and then check the draining
condition. (There is no problem in draining when the draining is completed within 20 seconds.)
141 Kinderkamack Rd, Park Ridge, NJ 07656 Tel: 201-782-1782 Fax: 201-782-1783 Web: www.amgair.com Email: info@amgair.com
Vinyl Chloride
(Outer diameter ø16mm)
Foamed Polyethylene
Drain pan
Band
Air Marketing Group LLC
ø70mm
Less than
150mm
Insulation
Drain hose
Indoor and outdoor
unit connection