Table 6 Troubleshooting Reference
Problem
Battery charging current is lower than the
charging set point during bulk charge mode.
Alarm does not sound when an error is
encountered.
975-0727-01-01
Possible Cause
Ambient (environment) temperature is
high.
Alarm is turned OFF.
Solution
Do not be alarmed, the unit is performing normally. The
charging current automatically de-rates at high ambient
temperature.
Improve ventilation. Make sure the unit's ventilation openings
are not blocked.
Press and hold the Select button for two seconds to disable (or
enable) the audible alarm. See "Display Panel Operation" on
page 16.