CRS-300 1:10 Redundancy Switch
Modem, RMI/TMI, and Switch Configuration
5.4.3

HSSI Interfaces via the CRS-336 TMI

Figure 5-8 and Figure 5-9 depict the CRS-336 TMI (CEFD P/N PL/12499 Rev B or later).
Jumpers JP1 & JP2 settings are factory-shipped as indicated. For modem-specific operations,
observe the following:
For CDM-625 modems, the jumper settings for 'CA to TA' Loop are as follows: Pin 1 to
Pin 3 (JP1 and JP2).
For SLM-5650A modems,the jumpers settings are as follows: Pin 1 to Pin 2; Pin 3 to Pin 4
(JP1 and JP2).
Front view
Figure 5-9. CRS-336 Jumpers JP1 & JP2 Detail (as shipped)

Figure 5-8. CRS-336 HSSI or Ethernet TMI Card

5–15
Jumpers JP1 & JP2: See Figure 5-9,
Tables 5-6 and 5-7 for details
Side View
Revision 16