Turn on the switch again (Fig. 01; pos. 1) and
press the continuous dose key (c) until thewater
comes out of the group, press stop and wait for
the machine to be underpressure.

6 - MAINTENANCE

For a proper working of the machine follow the
maintenance instructions given below.

6.1 Safety Rules

Do not wash the machine with water jets. Di-
sconnect the machine from the power supply by
turning the main switch on position 0. Taking
off the plug and turn off the water knob befo-
re carrying out maintenance and/or cleaning
operations.
In case of malfunctioning machine, do not carry
out any temporary repair and call immediately
the technical assistance service.
Should the power supply cable be damaged,
switch off immediately the machine, stop the
water supply and ask for the technical assist-
ance service. Do not replace it by yourselves.
Carry out the cleaning/maintenance when the
machine is cold, wearing preferably, protective
gloves.

6.2 Machine Cleaning

Clean the following pieces: steam nozzle and
hot water dispenser (every time they are used),
filter holder and filter, grills of warmer and
drain tray.

6.3 Scheduled Inspections

Wash the group every 15 days as follows: cla-
sp the holder of the blind filter to the group and
press many times the touchkey on the keypad.
N.B.: You can put special powder detergents
for coffee machines in the blind filter.
Clean the group gasket weekly with the proper bru-
sh supplied together with the machine (Fig. 07).
For the machine equipped with deconcentrator,
follow the enclosed maintenance instructions.
6.4 Safety Thermostat – Manual
Reset
Warning! The operation described here under
must strictly be carried out only by an appro-
priately qualified installation technician that has
been regularly authorised by the de-vice Manu-
facturer accordingly.
During device use or due to any device opera-
tion failure, the overheat control safety thermo-
stat will kick in for prevention of major damage
to the boiler set. To reset standard operations,
first troubleshoot and settle any possible device
crash or malfunction that actually caused the
safety thermostat to go off. Then, press the red
pushbutton (RESET) as illustrated in the Fig. 08
to reset all standard operating conditions.

6.5 Correct disposal of this product

(Waste Electrical & electronic equip-
ment)
(Applicable in the European Union and other
European countries with separate collection sys-
tems)
This marking shown on the product or
its literature, indicates that it should
not be disposed with other household
wastes at the end of its working life.
To prevent possible harm to the environment or
human health from uncontrolled waste disposal,
please separate this from other types of wastes
and recycle it responsibly to promote the sustai-
nable reuse of material resources. Household
users should contact either the retailer where
they purchased this product, or their local go-
vernment office, for details of where and how
they can take this item for environmentally safe
recycling. Business useres should contact their
supplier and check the terms and conditions of
the purchase contract. This product should not
be mixed with other commercial wastes for di-
sposal.