HP StoreOnce 2700 Installation And Configuration Manual page 65

Backup
Table of Contents

Advertisement

2.
Click Scan to perform a check on the currently installed firmware versions for all components
associated to the selected node.
This will populate the firmware tabs. This may take several minutes to run.
NOTE:
The scan will fail if a firmware update is already in progress.
3.
Look for components that have a Recommended Action of either Upgrade or Downgrade. After
you have run Scan or Scan All, components will automatically be selected for upgrade or
downgrade.
NOTE:
When the firmware updates are initiated, the backup devices will be taken offline.
Before performing this step, check that there are no outstanding backup jobs pending.
If there are only one or two, click in the appropriate check box to select them and click
Update Selected.
If there are many, click Update All. This will attempt to update all components that are in
the state where there is an update recommended; it will not try to update components
that do not need an update.
The Status field will show which components are being updated and which updates have
been completed.
4.
When all updates are completed, a reboot may be required.
5.
After the firmware has updated, HP recommends a cold reboot as follows:
Power off the StoreOnce Backup from the Maintenance page.
After the system has completely shut down, wait at least one minute before powering on
using the Power On button on the server(s).
NOTE:
A cold reboot is required if the network card or storage controller card firmware has
been updated. For other components, it is acceptable to reboot the system using the Reboot
option on the Maintenance page.
Firmware maintenance from the StoreOnce CLI
Procedure 1
1.
Run the StoreOnce CLI command to show the current status of firmware
# hardware show firmware <node|storage>
2.
Check the Action column to see if any firmware needs upgrading.
IMPORTANT:
Do not shutdown or reboot your system or any system component until step
5. Special instructions may apply. See step 5 for details.
3.
Before upgrading firmware, stop service sets.
serviceset stop all to stop service sets and ensure that no jobs are running
Wait one minute and check that service sets have stopped.
service show status to verify that all service sets have stopped. It may take up to one
minute for all service sets to stop.
# service show status
Service Set 1
-------------
Overall
#
Status
-------
: Not Running
Upgrading BIOS or hardware firmware components
65