Gas Connection - Baumatic BAU95EE Instruction Manual

Upright cooker 90cm
Table of Contents

Advertisement

Gas connection

The cooker must be connected to the gas supply with upstream connection of an
isolation valve in accordance with the respectively valid requlations. We
recommend that the isolation valve be fitted prior to the cooker to enable isolation
of the cooker from the gas supply. The valve must be easily accessable at all times
To find out the factory set gps type, see label at rear of cooker
The gas connection is via 1/2" compression. Connect the cooker to the gas supply
and check for gas soundness. NEVER use a naked flame to check for gas leaks.
Gas inlet (mm)-
From RH rear side: 35 mm
Up from floor: 590 mm
Gas inlet with different leg heights – mm
Min NG: 560
Ref NG: 590
Max NG: 595
Energy consumption
Burners
Gas type
Small
Natural
U-LPG
Medium
Natural
U-LPG
large
Natural
U-LPG
Wok
Natural
U-LPG
Oven/Grill
Nat gas
LP: 645
LP: 675
LP: 680
Pressure (kPa)
Injector
1.0
2.75
1.0
2.75
1.0
2.75
1.0
2.75
Gas inlet (mm)- LPG
From RH rear side: 35mm
Up from floor: 675 mm
(mm) Mj/hr
0.90
4.00
0.54
3.75
1.18
7.12
0.70
6.20
1.55
12.5
0.92
11.25
1.65
13.0
0.98
13.0
3000 W
Watts

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bau95eg

Table of Contents