2.15.4 E
PROM write selection (n12
You can choose whether the parameters are stored into the E
the parameter setting for computer communication. When performing parameter
write frequently, write them to the RAM.
Parameter
2
E
PROM write
n12 (342)
selection
The parameter number in parentheses is the one for use with the parameter unit (FR-
PU04).
REMARKS
* When the parameter setting is "not written to E
original values (values saved in the E
Factory
Name
Setting
0
2
PROM) at power-on reset or terminal reset.
)
Setting
Range
0: Written to RAM and E
1: Written to RAM only
0, 1
Not written to E
Setting is enabled when Pr. 30 = "1"
2
PROM" (setting=1), the settings return to the
150
2
PROM or not at
Remarks
2
PROM
2
PROM*