Product Information; Alert Symbols; Declaration Of Conformity - Technibel REVE 247C Operating Instructions Manual

Hide thumbs Also See for REVE 247C:
Table of Contents

Advertisement

CONTENTS
PRODUCT IDENTIFICATION
SIGNALING LAMPS
ACCESSORIES SUPPLIED WITH THE UNIT
INSTALLATION
BEFORE USING THE APPLIANCE
USING THE REMOTE CONTROL UNIT
EG
REMOTE CONTROL UNIT
HOW TO SET THE PRESENT TIME
COOLING
HEATING
AUTOMATIC OPERATION
DEHUMIDIFYING (DRY)
FAN ONLY
ADJUSTING THE FAN SPEED
SLEEP MODE
SETTING THE TIMER
ADJUSTING THE AIR FLOW DIRECTION
OPERATION WITHOUT THE REMOTE CONTROL UNIT
TIPS FOR ENERGY SAVING
TROUBLESHOOTING
HOW TO DISCHARGE THE CONDENSATE WATER
BOYLER CONNECTION KIT
CARE AND CLEANING

PRODUCT INFORMATION

If you have problems or questions concerning your Air
Conditioner, you will need the following information. Model
and serial numbers are on the nameplate applied on the unit.
Model No.
Serial No.
Date of purchase
Dealer's address
Phone number
NOTE
This air conditioner is equipped with cooling, drying and fan functions
functions
COOL /DRY/HEAT/FAN
when using the air conditioner. This product is covered by patent nr. 261412 issued on the 8th of Genuary 2009.

DECLARATION OF CONFORMITY

This product is marked
Directives.
- Low voltage no. 2006/95/CE.
- Electromagnetic
89/336/CEE, 92/31/CEE and 93/68/CEE.
This declaration will become void in case of
misusage and/or non observance though
partial of Manufacturer's installation and/or
operating instructions.
. Details on these functions are provided here following; refer on these descriptions
as it satisfies
compatibily
no.
2
2
3
3
6
7
8
9
9
9
9
9
10
10
10
11
11
12
12
12
13
14
14

ALERT SYMBOLS

The following symbols used in this manual, alert you to
potentially dangerous conditions to users, service personnel
or the appliance:
WARNING
This symbol refers to a hazard or unsafe practice which
can result in severe personal injury or death.
CAUTION
This symbol refers to a hazard or unsafe practice which
can result in personal injury or product or property damage.
COOL/DRY/FAN
OPERATING LIMITS
COOLING
OUTDOOR TEMPERATURE 43°C D.B.
MAXIMUM CONDITIONS
ROOM TEMPERATURE
OUTDOOR TEMPERATURE 19°C D.B.
MINIMUM CONDITIONS
ROOM TEMPERATURE
HEATING
OUTDOOR TEMPERATURE 24°C D.B./18°C W.B.
MAXIMUM CONDITIONS
ROOM TEMPERATURE
OUTDOOR TEMPERATURE -8°C D.B./-9°C W.B.
MINIMUM CONDITIONS
ROOM TEMPERATURE
DEHUMIDYFING (DRY)
OUTDOOR TEMPERATURE 43°C B.S.
MAXIMUM CONDITIONS
ROOM TEMPERATURE
OUTDOOR TEMPERATURE 16°C B.S.
MINIMUM CONDITIONS
ROOM TEMPERATURE
1
INFORMATION
CORRECT DISPOSAL OF THE
PRODUCT IN ACCORDANCE
WITH THE EUROPEAN
DIRECTIVE 2002/96/EC
At the end of its working life this
equipment must not be disposed of as
an household waste.
It must be taken to special local
community waste collection centres or
to a dealer providing this service.
Disposing of an electrical and electronic
equipment and its batteries separately
avoids possible negative effects on the
environment and human health deriving
from an inappropriate disposal and
enables its components to be
recovered and recycled to obtain
significant savings in energy and
resources.
In order to underline the duty to dispose
of this equipment and batteries
separately, the product is marked with
a crossed-out dustbin.
, cooling, drying, heating and fan
32°C D.B./23°C W.B.
19°C D.B./14°C W.B.
27°C D.B.
-
32°C B.S. / 80% R.H.
16°C B.S. / 80% R.H.