Temperature Settings; Temperature Table Of Controller - Takagi T-H3J-DV / 240H Installation Manual And Owner's Manual

Hide thumbs Also See for T-H3J-DV / 240H:
Table of Contents

Advertisement

Operation
Turn on the 120 VAC power supply to the unit (the water
1.
heater or the Multi-Unit Controller).
Press the "ON/OFF" button on the controller in order to
2.
turn the controller on.
3.
When ON, the STAND BY LED is lit.
It shows the set temperature on its display as shown in
4.
the picture on the right. (EX.: 50 °C)
Press the "HOT" button or the "COLD" button to set the
temperature setting of the unit.
Increasing temperature from 50 °C (120 °F) to 52 °C (125 °F) :
1. The water heater must be in Stand By to increase the
temperature.
2. Press the "HOT" button to set 50 °C (120 °F).
3. Press and hold the "INFO" button and the "HOT"
button for at least 3 seconds. The remote will emit a
beep and change to 52 °C (125 °F).
5.
4. Press the "HOT" button to set up to 60 °C (140 °F).
Increasing temperature above 60 °C (140 °F)
-T-H3-DV / 540H only-
1. The water heater must be in Stand By to increase the
temperature.
2. Press the "HOT" button to set 60 °C (140 °F).
3. Press and hold the "INFO" button and the "HOT"
button for at least 3 seconds. The remote will emit a
beep and change to 63 °C (145 °F).
4. Press the "HOT" button to set up to 70 °C (160 °F).

TEMPERATURE TABLE OF CONTROLLER

a) For T-H3J-DV / 240H and T-H3S-DV / 340H
°C
38
40
43
°F
100 105 110 115 120* 125 130 135 140
b) For T-H3-DV / 540H
°C
38
40
43
45
°F
100 105 110 115 120* 125 130 135 140 145 150 155 160
*Factory setting (Default): 50 °C

TEMPERATURE SETTINGS

-Set temperature-
45
50*
52
55
57
50*
52
55
57
41
Screen on the controller
Temperature controller
60
60
63
65
68
Page
Owner's Guide
Normal Operation
Remote controller
50 °C
(EX.:
)
70

Advertisement

Table of Contents
loading

This manual is also suitable for:

T-h3s-dv / 340hT-h3-dv / 540h

Table of Contents