CASE 3: Wrong connections between the "CHILD-1" unit and the "CHILD-2" unit
• If you connect the "PARENT" connector of the "CHILD-1" unit to the "1" connector of the
"CHILD-2" unit, the "CHILD-2" unit will operate as an individual unit, and will not be part of the
Easy-Link System.
PARENT unit
Connectors
Lower bank of
DIP switches
Communica on cable
Connecting two "PARENT" connectors together from two separate units may
damage the computer board. The communication cable has a female end and
a male end so it's impossible to have a PARENT-to-PARENT connection with the
WARNING
communication cable. Do not splice or modify connectors.
CASE 4: Remote controller connected to incorrect unit
• Either a temperature controller or a remote controller has to be connected to the "PARENT"
unit. If the remote controller is connected to a "CHILD" unit, it will only control that particular
individual "CHILD" unit and will not control the Easy-Link System as a whole.
• The temperature controller of the "CHILD" unit will not control the unit on the system.
PARENT unit
Connectors
Lower bank of
DIP switches
Communica on cable
CHILD-1 unit
Connectors
Connectors
Lower bank of
DIP switches
CHILD-1 unit
Connectors
Lower bank of
DIP switches
32
Page
Installation Manual
Installation
CHILD-2 unit
Lower bank of
DIP switches
Wrong
Connections
TM-RE42
Remote controller
Wrong Connections