Direct Vent Gas Fireplace Models: DV360, DV580 INSTALLER / CONSUMER SAFETY INFORMATION PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE WARNING! IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
DV360/580 Series Direct Vent Gas Fireplace Table of Contents PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE. Thank you and congratulations on your purchase of a CFM Corporation fireplace. IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty.
DV360/580 Series Direct Vent Gas Fireplace Installation & Operating Instructions This gas appliance should be installed by a qualified installer in WARNING: Check with your electronics manufac- accordance with local building codes and with current CSA- turer before installing a television or other electronic B149.1 Installation codes for Gas Burning Appliances and...
DV360/580 Series Direct Vent Gas Fireplace Fireplace Dimensions (Installed as Top Vent) Rough Opening Depth Recessed Nailing Flange S - Rough Opening Width Rough Opening Height Electrical Gas Line Access Access Fig. 2 Fireplace specifications and framing dimensions. 2261b Ref.
DV360/580 Series Direct Vent Gas Fireplace Fireplace Dimensions (Installed as Rear Vent) Rough Opening Depth Recessed Nailing Flange R - Rough Opening Width Rough Opening Height Electrical Gas Line Access Access Fig. 3 Fireplace specifications and framing dimensions. 2261a Ref.
DV360/580 Series Direct Vent Gas Fireplace Clearance to Combustibles Top of unit to ceiling ......... 36” (914 mm) Front of unit to combustibles ....36” (914 mm) Appliance Top of standoff ........0” (0 mm) Bottom ............. 0” (0 mm) Side ............
DV360/580 Series Direct Vent Gas Fireplace The gas control is equipped with a captured screw type High Elevations pressure test point, therefore it is not necessary to pro- Input ratings are shown in BTU per hour and are vide a 1/8” test point up stream of the control.
The EB-1 electrical junction box has been supplied standard on the DV360/580 models to allow for the easy installation of an optional fan kit. To connect the EB-1 box to the house electrical supply, follow the steps below.
CAUTION: Remove insulation. Insulation extends Optional Top Vent Application beyond opening in top of unit. Be sure to The DV360/580 fireplace is shipped as a rear vent unit. remove all insulation before completing If the layout requires a top vent, convert the unit follow- conversion.
DV360/580 Series Direct Vent Gas Fireplace General Venting There must not be any obstruction such as bushes, gar- Your fireplace is approved to be vented either through den sheds, fences, decks or utility buildings within 24” the side wall, or vertical through the roof.
DV360/580 Series Direct Vent Gas Fireplace General Venting Information - Termination Location INSIDE CORNER DETAIL Fixed Fixed Closed Closed Fixed Operable Closed AREA WHERE TERMINAL IS NOT PERMITTED VENT TERMINATION AIR SUPPLY INLET CFM145a Canadian Installations US Installations CFM145a A = Clearance above grade, veranda, porch, 12”...
DV360/580 Series Direct Vent Gas Fireplace Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors. Inside Corner Recessed Location Outside Corner Combustible 6"(152mm) Combustible 6"(152mm) Noncombustible 2"(50mm) Noncombustible 2"(50mm) Balcony - Balcony - with perpendicular side wall with no side wall C = Maximum depth of 48"...
DV360/580 Series Direct Vent Gas Fireplace Twist Lock Pipes When using twist lock pipe it is not necessary to use sealant on the joints. The only areas of the venting system that need to be sealed with high temperature silicone sealant are the collars on the fireplace and termination, and the sliding joint of any telescopic vent section used in the system.
Page 15
DV360/580 Series Direct Vent Gas Fireplace Vent Opening for Combustible Walls 9³⁄₈” (240 mm) Rear Vent Top View 20” (508 mm) Max. 10³⁄₈” (265 mm) DVR584-600 Framing Detail Fireplace Hearth Fig. 20 Rear vent application, no elbows. 20” Opening for Noncombustible Wall DVR584-600 20”...
DV360/580 Series Direct Vent Gas Fireplace Finished Wall Rise Vent Termination FP1472 Fig. 26 There must be a 1/2” rise per foot length. Vertical Sidewall Application Since it is very important that the venting system maintain its balance between the combustion air intake and the flue gas exhaust, certain limitations...
Page 17
DV360/580 Series Direct Vent Gas Fireplace 7’ 3 x 90° 3 x 90° Elbows (2.1 m) Elbows 10’ (3 m) FP1176 8’ Fig. 27 Maximum three (3) 90° elbows per installation. (2.4 m) 36" (914mm) Max. 36" V584-201 (914mm) Max.
Page 18
DV360/580 Series Direct Vent Gas Fireplace Vertical Sidewall Installation Max. Length Adjustable Zero Twist Lock Pipe 12” (305 mm) Clearance Sleeve Step 1 #8 Screws (2) Locate vent opening on the wall. It may be necessary to first position the fireplace and measure to obtain hole #8 Screws location.
Page 19
DV360/580 Series Direct Vent Gas Fireplace 4” Flex Vent Pipe 12" (305mm) Spacer Spring 6" (152mm) 5" (127mm) 6³⁄₄" (172mm) FP1474 FP1182 Fig. 36 Install spacer springs. Fig. 35 Horizontal length requirement. Step 4 Step 7 FP1474 Install the 4” (102 mm) flex vent pipe to the appliance Apply high temperature sealant to 4”...
DV360/580 Series Direct Vent Gas Fireplace Do not back fill around snorkel. Below Grade Installation A clearance of at least 4” must be main- When it is not possible to meet the required vent ter- tained between the snorkel and the soil.
Page 21
DV360/580 Series Direct Vent Gas Fireplace Vertical Through-the-Roof Installation Max. Height 40’ (12.2 m) 1. Locate your fireplace. Min. Height 8’ (2.4 m) 2. Plumb to center of the (4”) flue collar from ceiling above and mark position. 3. Cut opening equal to 9³⁄₈” x 9³⁄₈” (240 mm x 240 mm).
Page 22
DV360/580 Series Direct Vent Gas Fireplace 3 #5 Sheet Metal Typical Roof Screws per Joint Support Typical Ceiling Application Support Sealant Application FP1184 Storm Collar Fig. 43 Venting supports. FP1184 Typical roof/ceiling support apps. Min. 2' (610 mm) TWL101a Fig. 45 Roof flashing.
DV360/580 Series Direct Vent Gas Fireplace Operating Instructions Window Frame Glass Information Assembly Only glass approved by CFM Corporation Fireplace Front should be used on this fireplace. • The use of any non-approved replace- ment glass will void all product warranties.
DV360/580 Series Direct Vent Gas Fireplace Screw Screw Log Identification Chart Burner Logs DV360 DV580 Log Front Left 20010673 Log Front Right 20010672 Log Rear 20010675 Log Top Left Grate Log Top Right 20010676 Hearth Panels Log Front Center Front of Unit...
Page 26
DV360/580 Series Direct Vent Gas Fireplace 2. Place the log overlay. Hold the overlay with the flat side Figure 51 down and large cut out for the middle flame on the right. Set the overlay on top of the burner toward the left front...
Page 27
DV360/580 Series Direct Vent Gas Fireplace 6. Place the log top cen- Figure 54 ter. Hold the log with Log Top Right Log Top Center the pointed end toward the back. Match the Rear two holes on the bot- tom of the log with the two pins on the top of the log front right.
DV360/580 Series Direct Vent Gas Fireplace Flame Characteristics Burner Lava Rock Placement It is important to periodically perform a visual check of Place burner lava rock on the burner in front of the front the pilot and the burner flames. Compare them to the logs.
Page 29
DV360/580 Series Direct Vent Gas Fireplace Yellow Flame Yellow Flame LG444 DV360 Red Glow ����� ����� �� ��� ������ ���� ��� LG396 DV580 Red Glow Fig. 59 Correct burner flame apperance for DV360 and DV580. ����� ����� ��� ������ ���� 20010667...
DV360/580 Series Direct Vent Gas Fireplace Lighting and Operating Instructions FOR YOUR SAFETY READ BEFORE LIGHTING WARNING:If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This heater has a pilot which must be lit manu- Follow the gas supplier’s instructions.
DV360/580 Series Direct Vent Gas Fireplace Lighting and Operating Instructions For Fireplaces equipped with SIT822 Gas Valve (EN or EP) Warning: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury and loss of life.
DV360/580 Series Direct Vent Gas Fireplace Instructions for RF Comfort Control Valve Shut Off Procedure The Comfort Control Valve allows remote control of If the manual switch is in the REMOTE position, the temperature, fan and flame appearance. transmitter can shut off the main burner and fan. How-...
Page 33
DV360/580 Series Direct Vent Gas Fireplace Delay Timer Mode Pilot Assembly The shut off delay timer has a maximum of 2 hours and a minimum of zero minutes. To change the timer level, press the time key followed by an arrow key. Pushing the key once will change the timer by 10 minutes.
Page 34
DV360/580 Series Direct Vent Gas Fireplace LED Count Service Action Replace valve Confirm stepper motor connection exists Confirm fan connection exists and works Confirm gas type; jumper in place Replace thermopiles Turn fan ON NOTE: Some keys are not active.
Page 35
DV360/580 Series Direct Vent Gas Fireplace Comfort Valve System Control Sequence of Operation with Transmitter Set manual switch Five minute wait to local or remote period Light pilot burner Did the LED stop Review LED fail- blinking? ure analysis Release pilotstat...
DV360/580 Series Direct Vent Gas Fireplace Troubleshooting - Honeywell VS8421 Remove Window Frame Assembly Before Service Work START CHECK • Supply Line Hooked Up Gas Supply On • Shutoff Valve Open • Lockout Has Engaged. Wait 60 Seconds And Try Again.
DV360/580 Series Direct Vent Gas Fireplace Troubleshooting the Gas Control System SIT NOVA 820 Millivolt Valve NOTE: Before trouble shooting the gas control system, be sure external gas shut off is in the “On” position. WARNING: Before doing any gas control service work, remove glass front.
DV360/580 Series Direct Vent Gas Fireplace Troubleshooting the Gas Control System START •TURN GAS SUPPLY OFF CHECK: • LINE VOLTAGE (120VAC) • LOW VOLTAGE TRANSFORMER (19.5 minimum VAC) • TURN ON/OFF SWITCH • ON/OFF SWITCH TO CALL FOR HEAT "ON"...
2. Insure the rubber gasket (D) is properly positioned and install the new HI/LO pressure regulator assem- To convert the DV360/580 units for use with a different bly to the valve using the new screws (E) supplied gas follow these instructions. Before proceeding, turn with the kit.
Page 40
DV360/580 Series Direct Vent Gas Fireplace 3. Using a 1/2” open end wrench remove the orifices. Gasket (Fig. 67) Burner Housing Mixing Tube Front Burner Orifice (Refer to Table on Page 42) Natural Rear Burner Orifice (Refer to Table on Page 42)
DV360/580 Series Direct Vent Gas Fireplace moval Section” Page 24, Fig. 47) Burner Pan Shutter 2. Remove logs if previously installed. CAUTION: Logs Retaining may be hot! Screw 3. Remove and replace plug on lower right hand side of the valve; Red for LP and blue for NG. (Fig. 74) 4.
Page 42
DV360/580 Series Direct Vent Gas Fireplace unfastening the screw on the tray to the right side of 2. Remove pilot orifice with needlenose pliers. (Fig. 77) the orifice. Slide the bracket/gasket assembly over 3. Install conversion pilot orifice. the fitting on the manifold toward the back with the 4.
DV360/580 Series Direct Vent Gas Fireplace Maintenance Burner and Burner Compartment To obtain proper operation, it is imperative that the pilot It is important to keep the burner and the burner com- and burner’s flame characteristics are steady, not lifting partment clean.
DV360/580 Series Direct Vent Gas Fireplace 1. DV360 1 DV580 3a,b 22a-d 19 a/b 26a,b 24 a/b 35a/b 25 a/b 59a,b 57a,b 60a,b • 65a,b 72a,b 71a,b CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice.
Page 45
DV360/580 Series Direct Vent Gas Fireplace DV360/580 (continued) Ref. Description DV360 DV580 Log Set 20010671 10007545 Log Front Left 20010673 10007540 (E9) Log Front right 20010672 10007541 (E10) Log Rear 20010675 10007539 (E8) Log Top Left 10007543 (E12) Log Top Right...
Page 46
DV360/580 Series Direct Vent Gas Fireplace DV360/580 (continued) Ref. Description DV360 DV580 Nut Electrode 57886 57886 Pilot tube 1/8” x 24” long w/fittings (SIT Pilot) 10001296 10001296 Thermocouple - RN/RP 53373 53373 Cable Ignitor - RN/RP 53194 53194 Thermopile - RN/RP...
57899 Tubing 3/8” OD Aluminum 20010564 Nut 3/8” ID Brass, Compression 7523136 *NOTE: For DV360, when ordering Manifold Assembly, also order #75 (qty 1) and #76 (qty 2). Fuel Conversion Kits Natural Gas to LP DV360RN/EN/RFN Kit # 20010752 DV580RN/EN...
DV360/580 Series Direct Vent Gas Fireplace Optional Accessories Method A Fan Kits Route the 6’ (1.8m) lead fitted to the unit to a conve- FK12 Fan Assembly niently located wall socket. 1. Open louvre assembly bottom. Method B 2. Install FK12 fan in back of unit between hearth sup- If the EB-1 receptacle box (Pt.
Fig. 83 Rear ceramic panel placement. Ceramic refractory panels are available to line the fire- box area. Decorative Bay Windows H102 Unit Kit Model rear ceramic support The bay window kit is available for the DV360 only. DV360 DV360CRSS Sandstone 2/23/99 djt DV360 DV360CRR Installation...
DV360/580 Series Direct Vent Gas Fireplace For Use in Mobile Homes: Model DV360RMH This appliance may be installed as an OEM installation in a manufactured home (US only), or a mobile home; it must be installed in accordance with the manufacturer’s instructions and the manufactured home construction and safety standard Title 24 CFR Part 3280, or Standard for Installation in Mobile Homes CAN/ CSA Z240 MH.
Page 51
DV360/580 Series Direct Vent Gas Fireplace a) Using a Torx T20 or slotted screwdriver, remove and save the three pressure regulator mount- ing screws (A), pressure regulator tower (B) and diaphragm (C). b) Ensure the rubber gasket (D) is properly posi-...
Page 52
DV360/580 Series Direct Vent Gas Fireplace 20010667...
LIMITED LIFETIME WARRANTY DV360/580 Series Direct Vent Gas Fireplace PRODUCT COVERED BY THIS WARRANTY All Vermont Castings gas stoves, gas inserts, and gas fireplaces, and all Majestic brand gas fireplaces equipped with an Insta-Flame Ceramic Burner, or standard steel tube burner.