Download Print this page

Assa Abloy Code Handle Fitting And Operating Instructions page 2

Code
Hide thumbs Also See for Code Handle:

Advertisement

operating instruction
Batteries
ASSA ABLoy Code Handle is supplied with
2 pcs CR2 batteries installed. The lifetime of
the batteries should be at least a couple of
years depending on number of operation
and the effect in the batteries. If the light
signals red when pushing down a key it is
time to change batteries. The handle will
remember all codes during the change.
It is important to choose batteries of good
quality when changing. Use CR2 batteries of
well known brand.
When changing batteries follow the instruc-
tion on image 1-3 and follow necessary
safety precautions:
• Install the batteries correctly, see image 2.
Be aware of the polarity
• Do not mix used and new batteries. Do
not mix different brands.
• Change both batteries at the same time
• Do not incinerate batteries.
• Properly dispose of used batteries
• Do not leave them within the reach of
children.
1. Unscrew the battery cover with the
enclosed security bits.
Master CHD manual_M 2198.1012_KT810E.indd 2
Security
If a wrong code is entered five times the
handle is locked-out for 3 minutes and the
light will flash red every five seconds. To pass
the lock-out, enter the correct code twice
and then once more to gain access.
user codes
ASSA ABLoy Code Handle has room for 9
different user codes which can be program-
med by use of the selected administrator
code.
Add or change a code in the memory:
1. Press the padlock key until a red, steady
light appears.
2. Enter the administration code within 5
sec. The light shines green.
3. To store the code in one of the 9 memory
positions use key number 1 and press
the number of times corresponding to
selected memory position; one press for
memory position 1 and two presses for
memory position 2 etc.
4. Wait until a green, steady light appears.
5. Enter the new user code, consisting of 4,
5 or 6 digits.
2. Press the handle down and let the two
3. Replace the battery cover.
batteries fall out.
Fit two new batteries. Be sure to fit them in
correct position.
6. Press the padlock key to confirm or wait
until the green light is turned off.
7. More user codes can be storaged on the
remaining memory positions. Follow the
instructions above and store according
to point 3.
Delete a code from memory:
1. Press the padlock key until a red, steady
light appears.
2. Enter the administration code within 5
sec. The light shines green.
3. Select which one of the 9 memory
positions to be deleted by pressing key
number 1 the required number of times;
one time for memory position 1 and two
times for memory position 2 etc.
4. Wait until a green, steady light appears.
5. Delete by pressing the pad lock key. The
light shines red and the selected memory
place is now deleted.
6. To delete more memory positions repeat
the instruction above and indicate cor-
responding memory position by following
instructions in point no 3.
Sound signal
The handle is delivered with the sound
signal on and can be turned off/on as
follows:
1. Press the padlock key until a red, steady
light appears.
2. Enter the administration code within 5
sek. The light shines green.
3. Press one time on key number 2 to turn
off/turn on the sound. A weak signal
indicates that the sound is off and a
strong double signal indicates that the
sound is on.
4. Press the padlock key to confirm or wait
until the green light is turned off
Automatic locking
The handle is delivered in manual mode.
Automatic locking within 9 sec after correct
code is keyed can be selected provided that
the handle is back in horizontal position
within this time.
To change mode follow the instructions
below:
1. Press the padlock key until a red, steady
light appears.
2. Enter the administration code within 5
sec. The light shines green.
3. Press one time on key number 3 to
change the mode to/from automatic
locking.
4. Press the pad-lock key to confirm the
change or wait until the green light stops.
Temporary leave open function when in
automatic locking mode
Key the correct user code and directly after
the light stops flashing, press button 1 and
4 at the same time. The door is now left
unlocked until the next time either the lock
button or the user code is keyed, where after
it goes back into automatic locking mode. 
memory reset
The handle can be reset back to factory
settings by changing the administrator
code. (Read before fitting, opposite side)
The handle is supplied as:
• No user code set
• Sound signal on
• Auto-lock off
DocumeNT THe coDeS
Store safety
Administration code:
Code ______________________
user codes:
Code 1 _____________________
Code 2 _____________________
Code 3 _____________________
Code 4 _____________________
Code 5 _____________________
Code 6 _____________________
Code 7 _____________________
Code 8 _____________________
Code 9 _____________________
ASSA ABLoy, the global leader
in door opening solutions.
2010-12-13 10.59

Advertisement

loading