TROUBLESHOOTING
11.10. Defect: Ignition
Cause of Defect
a - Spark
plugs defective
b - Improper connection of
the
ignition cables
to the spark plugs
c - Magneto
distributor
cap defect
d - Breaker contact damage,
improper contact gap
or dirt
e - Magneto grounding
circuit fault
Remedy
Check,
clean
and
replace
spark plugs, if required
Check for correctconnection
and correct, as required
Cleam,
dry.
replace,
if defective
Clean breaker contacts,
replace and adjust contact
gap, as required
Check for correct wiring
11.11. Defect: Electrical Accessories
Cause of Defect
Remedy
a - Alternator not charging Check brushes
and replace,
if required
Check
rotor
winding
for
continuity (by
means of an
ohmmeter,
circuit
tester
etc.
Alternator
rotor
replacement
Check
for
correct
connection of leads
b
~
Starter inoperative
Check brushes
and replace,
if required
Check battery for charge
Check
for
correct
connection of leads
Constact
manufacturer
or
replace
electrical
accessories, if not succeeding
in determining cause of
defect.