MIKRON lilA
A@."
cz
........
6. Instruction for Maintenance.
....
Engine maintenance is performed either after reaching of operating hour interval
(periodic checks) or according to the time limit.
6.1
Daily Check
It is performed before every flight day. however, after each 10 flight hours maximum.
Ignition "OFF"
Examine:
screw. nut and bolt tightening and locking
-
cock pull rod and choke pull rod connection and locking and their free operation
in whole range
ignition cables fastening and connection to the spars
-
leakproofuess and locking of fuel and oil hose connections
-
oil penetration from connections on engine
-
engine to airframe attachment, silentblock condition
-
exhaust pipe and silencer for cracks, burns out and corrosion
-
oil in tank condition, refill to maximum
Drain and clean the fuel cleaner.
Perform engine test in the range according to 5.1, 5.2 and 5.3 points ..
6.2
Periodic check
Inspection must be performed in the following interval.at the latest.
1. after first 25
+
2 operational hours
2. after each 50
+
5 operational hours ..
3. after each 100
+
10 operational hours or Ix per 12 months - annual inspection
4. overhaul after 1200 +200perational hours or 15 years
Date of issue: 8/99
Decument No.: 610902