Encoders :
But before doing this the module must be disconnected from the terminal strip located on the back
A
of the unit (see
To access the encoders, remove the top. (See «To remove top»).
Remove the control knop, by pulling off.
Disconnect the electric cable from the induction hob to the encoder (see
Unscrew the two screws, (see
Remove the encoder and replacewith the new one.
Replace the components, in reverse order.
Encoder reference
Induction unit :
But before doing this the module must be disconnected from the terminal strip located on the back
A
of the unit (see
To access the induction unit, remove the top (See «To remove top»).
Disconnect all the cable for the induction hob to the terminal blocks and the encoders cable (see
A
1
, figure
).
Remove the hob and rest it on a stable surface. Ensure the vitroceramic hob is placed on a clean,
soft surface so that the glass top is not scratched (see figure
INSTALLER'S MANUAL
SERVICING / REPAIRS
1
, figure
).
C
, figure
A
: 65 225006
1
, figure
).
Cluny induction - Ft 151a - GB - Rév 05 - Modifié le : 07/10/2013
3
) securing the encoder to the control panel.
1
4
).
B
2
, figure
).
B
C
2
3
12/31