OPTIONAL REMOTE,
WALL SWITCH OR THERMOSTAT
(0N CERTIFIED UNITS ONLY)
BLACK
ON/OFF
FLAME
SENSOR/SPARKER
IGNITION
MODULE
NEUTRAL
For Direct Spark Ignition (DSI) Wiring
L2
(NEUTRAL)
JUNCTION
OPTIONAL FAN
L1
BOX
(HOT)
SWITCHES
120VAC
REM
FAN
GROUND
GROUND
TO
FIREPLACE
CHASSIS
WHITE
GAS
VALVE
REMOTE OUTLET
FAN OUTLET
GROUND
DSI CONTROL VALVE
WHITE
BLUE
WHITE
BLACK
GREEN
BLUE
ON/OFF SWITCH
CONNECTORS
HOT
CAUTION: LABEL ALL WIRES PRIOR TO DISCONNEC-
TION WHEN SERVICING CONTROLS. WIRING ERRORS
CAN CAUSE IMPROPER AND DANGEROUS OPERATION.
VERIFY PROPER OPERATION AFTER SERVICING.
48
IGNITOR
DSI MODULE